Evidence map›Paper›PMID 42244814›Full record

ArticleArXiv2026

Weight-Guided Constraints for Body Model and Lead Selection in Pediatric CIED MRI Safety Simulations.

Safa Hameed, Kaylee Henry, Fuchang Jiang, Bhumi Bhusal, Halley Dillenbeck, Lindsey Gakenheimer-Smith, Gregory Webster, Laleh Golestanirad

Abstract readPreprint
In one paragraph

Article in ArXiv, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Safa HameedDepartment of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
Kaylee HenryDepartment of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
Fuchang JiangDepartment of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
Bhumi BhusalDepartment of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
Halley DillenbeckDivision of Cardiology, Department of Pediatrics, Ann & Robert H. Lurie Children's Hospital, Chicago, IL, USA.
Lindsey Gakenheimer-SmithDivision of Cardiology, Department of Pediatrics, Ann & Robert H. Lurie Children's Hospital, Chicago, IL, USA.
Gregory WebsterDivision of Cardiology, Department of Pediatrics, Ann & Robert H. Lurie Children's Hospital, Chicago, IL, USA.
Laleh GolestaniradDepartment of Biomedical Engineering, Northwestern University, Evanston, IL, USA.

Funding

Safe and Effective MRI for Pediatric Patients with a Cardiac Implantable Electronic DeviceR01HL168859 · NHLBI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI Laleh Golestani Rad, Daniel Kim · 2024 to 2026
$2.0M
Assessing RF heating of active implantable medical devices in low-field MRI systemsR01EB036272 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI Laleh Golestani Rad · 2024 to 2026
$1.6M
Novel MRI coil technology for safe imaging of children with implantsR01EB034377 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2023 to 2025
$1.5M
NHLBI NIH HHS R01 HL168859NIBIB NIH HHS R01 EB034377NIBIB NIH HHS R01 EB036272
6 · The paper itself

Abstract

Pediatric patients with cardiac implantable electronic devices (CIEDs) face limited MRI access due to RF-induced heating, and computational modeling is increasingly used to characterize this risk. The validity of these simulations, however, depends on pairing body models with clinically realistic lead configurations, guidance that is currently lacking. We retrospectively analyzed 302 CIED surgeries in 281 pediatric patients to derive weight-based constraints for simulation design. Weight alone discriminated epicardial from endocardial lead implantation with AUC = 0.90, and adding age and height yielded no improvement, supporting weight as a sufficient single-parameter selection metric. The probabilistic crossover between approaches occurred at 44 kg, substantially higher than the 10 to 15 kg threshold commonly cited in the literature, with a broad transition zone of 21 to 66 kg in which both lead types were routinely used. Lead length was likewise weight-constrained: only 25 cm leads were observed in patients below 6 kg, and leads of 45 cm or longer were uncommon below 50 kg. These findings yield a three-tier framework, with epicardial-only configurations below 21 kg, dual configurations within 21 to 66 kg, and weight-thresholded lead lengths throughout, enabling MRI safety simulations to focus on clinically realizable anatomy and device combinations.

Indexed as

computational modelingelectromagnetic simulationsMRI safetypediatricRF heating

Identifiers

PMID42244814
PMCPMC13232433

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.