Evidence map›Paper›PMID 42240755›Full record

ArticleMedical & biological engineering & computing2026

Elevated-rim liner positioning in total hip arthroplasty: a compromise between dislocation biomechanics and range of motion.

Tao Feng, Chengshuai Zhang, Dongyang He, Hao Tang, Xiaogang Zhang, Yali Zhang, Yixin Zhou, Zhongmin Jin

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tao FengTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.
Chengshuai ZhangDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 100035, China.
Dongyang HeTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.
Hao TangDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 100035, China.
Xiaogang ZhangTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China. xg@swjtu.edu.cn.ORCID http://orcid.org/0000-0003-4608-5401
Yali ZhangTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.
Yixin ZhouDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 100035, China.
Zhongmin JinTribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.

Funding

National Natural Science Foundation of China 52035012
6 · The paper itself

Abstract

Dislocation remains a common complication after total hip arthroplasty (THA). Elevated-rim liners may enhance stability, but their effectiveness depends on rim orientation and cup position. This study aimed to develop a capsule-informed framework integrating dislocation biomechanics and impingement-free range of motion (IFROM) to optimize elevated-rim liner positioning. A fiber-reinforced finite element (FE) model of the hip capsule was developed and calibrated using cadaveric data. A THA model was used to quantify IFROM across combinations of liner orientation and cup position, defining impingement-free safe zones (IFSZs). Liner edge contact pressure, plastic strain, and resistive moments were evaluated under three representative dislocation maneuvers. The framework accurately reproduced capsular mechanical behavior and identified IFSZs. Hyperextension produced the most severe edge loading. Posteroinferior rim orientation reduced edge loading and increased resistive moments, particularly for posterior dislocation. A clear trade-off existed between maximizing resistive moment and preserving IFROM. Liner positioning cannot rely solely on geometric parameters. A multi-objective strategy balancing IFROM and resistive moments while maintaining safe edge loading is required. The proposed framework provides a quantitative tool for patient-specific planning to reduce mechanical failure and improve joint stability after THA.

Indexed as

Arthroplasty, Replacement, HipHip DislocationRange of Motion, ArticularBiomechanical PhenomenaFinite Element AnalysisHip JointHip ProsthesisHumansDislocationEdge loadingElevated-rim linerHip capsuleRange of motion

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.