Evidence map›Paper›PMID 42239934›Full record

ArticleHardwareX2026

Optically isolated High-Speed data acquisition system for ion mobility spectrometry.

Jannik Wuttke, Tim Kobelt, Jonas Winkelholz, Martin Lippmann, David Bailey, Stefan Zimmermann

Abstract read
In one paragraph

Article in HardwareX, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jannik WuttkeLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
Tim KobeltLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
Jonas WinkelholzLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
Martin LippmannLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
David BaileyLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
Stefan ZimmermannLeibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many sensor applications require sensor data transmission from high electrical potential to ground potential. For example, the instrumental setup of ion mobility spectrometers (IMS) can be greatly simplified by operating the ion source at ground potential and the detector at high electrical potential. This operation mode demands the ion current signal to be transmitted electrically isolated from the detector to the data acquisition system. Furthermore, many applications require high sampling rate and high resolution of the data acquisition. Therefore, a novel open-source high-speed data acquisition system is presented that enables optically isolated data acquisition and facilitates a signal-to-noise ratio (SNR) of up to 87.5  dB with an adjustable sampling rate of up to 12.5 MS/s. To minimize the number of communication lines, an analog-digital-converter (ADC) with a serial high-speed interface is used instead of a parallel interface. Thereby, the communication lines can simply be isolated by only two common, low-cost optical network transceivers. In order to increase the SNR of the data acquisition, a commercial system on a chip (SoC) module digitally low-pass filters the ADC data and then reduces its sampling rate. An ethernet with TCP/IP connection is used to retrieve, visualize and save the recorded measurement data. In addition to the optically isolated high-speed data acquisition, the data acquisition system has one trigger pulse input channel and seven configurable pulse output channels, which enable compatibility with further control electronics.

Indexed as

Data acquisitionHigh-speedIMSIon mobility spectrometryJESD204 interfaceOptical isolation

Identifiers

PMID42239934
PMCPMC13226932

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.