ArticleCommunications engineering2026
Single-Pixel Tactile Skin via compressive sampling.
Article in Communications engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Large-area, high-speed tactile skins could improve robotics, prosthetics, and human-machine interfaces, but scaling them is limited by wiring complexity and readout bandwidth. We introduce Single-Pixel Tactile Skin (SPTS), a flexible, daisy-chainable tactile array that implements compressive sampling directly in hardware. Each sensing element uses a miniature low-cost microcontroller to apply programmable analog weights, while all pixel currents are summed into a single output channel. Repeating this process yields global projections from which tactile images are reconstructed using sparse recovery, reducing the measurements required relative to raster scanning. In a 10×10 array, SPTS achieved ≥98% object classification accuracy with 20 measurements, corresponding to an effective 3500 FPS, and captured an 8 ms projectile impact in 23 reconstructed frames. Because reconstruction quality improves progressively with measurement count, SPTS can rapidly localize contact from sparse data and refine tactile images over time, enabling scalable, responsive tactile sensing for physical interaction and control.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.