Evidence map›Paper›PMID 42234368›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026

Safety and performance of the novel balloon-in-basket pulsed field ablation system: initial 100-patient experience at a high-volume electrophysiology center.

Roland Richard Tilz, Sascha Hatahet, Charlotte Eitel, Sorin Popescu, Roman Mamaev, Kohei Ukita, Mirco Küchler, Suzanne de Waha, Karl-Heinz Kuck, Jan-Per Wenzel

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Roland Richard Tilz *Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Sascha Hatahet *Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany. Sascha.hatahet@uksh.de.
Charlotte EitelDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Sorin PopescuDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Roman MamaevDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Kohei UkitaDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Mirco KüchlerDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Suzanne de WahaDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Karl-Heinz KuckDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
Jan-Per WenzelDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe balloon-in-basket(BiB) pulsed field ablation(PFA) system integrates real-time electroanatomic mapping and contact sensing to streamline workflows, but clinical experience remain limited. The aim was to descriptively evaluate procedural performance, acute safety, and feasibility of the BiB-PFA-system in consecutive atrial fibrillation(AF) patients treated at a high-volume electrophysiology center.

methodsThis prospective study included the first 100 consecutive patients undergoing pulmonary vein isolation(PVI) with the BiB-PFA-system between 01/2024 and 10/2025. The initial 30 patients were part of VOLT

resultsPatients were 68[62;76] years old, 41% were female, and 47% had paroxysmal AF. Median procedure duration was 59[48.0;71.0] and BiB-dwell time 26.0[21.0; 37.5] min. For VOLT™-CE-Mark-study patients, procedure and BiB-dwell times were 72.5[67.3;85.0] and 25.0[21.0;28.2] min, compared with 48.5[36.5;59.0] and 23.5[18.3;36.3] min in non-study patients. All PVs were successfully isolated with 100% first-shot success using a median of 4 applications. Additional ablations included posterior wall(41%), anterior line(5%), CTI(3%), and SVC isolation(6%). One groin complication(1%) requirng intervention occured. Same-day discharge was conducted in 8%, limited primarily by institutional policy. Freedom from atrial tachyarrhythmia was 86% at median follow-up of 293[184;364]days.

conclusionThe BiB-PFA system enabled PVI with consistent first-shot success and a low rate of periprocedural complications. Follow-up available in a subset of patients suggested favorable early rhythm outcomes. TAKE HOME MESSAGE: • This study provides the first clinical experience with the BiB-PFA-system, characterizing procedural workflows and acute safety in routine practice • This study reports the first mid-term follow-up data for the BiB-PFA system, demonstrating an 86% freedom from atrial tachyarrhythmia after a 60-day blanking period at a median follow-up of 293 [184-364] days. • The integrated mapping-and-ablation design enabled efficient PVI with consistent first-shot success and short procedure times. • Ablation strategies beyond PVI-including posterior wall ablation, anterior line ablation, CTI ablation, and SVC isolation-were feasible and could be performed safely within the same workflow. • A low rate of periprocedural complications was observed in this cohort, including one vascular complication requiring intervention, supporting a favorable acute safety profile in a high-volume electrophysiology center.

Indexed as

Atrial fibrillationBalloon-in-basketPulmonary vein isolationPulsed field ablationWorkflow

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.