ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026
Safety and performance of the novel balloon-in-basket pulsed field ablation system: initial 100-patient experience at a high-volume electrophysiology center.
Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe balloon-in-basket(BiB) pulsed field ablation(PFA) system integrates real-time electroanatomic mapping and contact sensing to streamline workflows, but clinical experience remain limited. The aim was to descriptively evaluate procedural performance, acute safety, and feasibility of the BiB-PFA-system in consecutive atrial fibrillation(AF) patients treated at a high-volume electrophysiology center.
methodsThis prospective study included the first 100 consecutive patients undergoing pulmonary vein isolation(PVI) with the BiB-PFA-system between 01/2024 and 10/2025. The initial 30 patients were part of VOLT
resultsPatients were 68[62;76] years old, 41% were female, and 47% had paroxysmal AF. Median procedure duration was 59[48.0;71.0] and BiB-dwell time 26.0[21.0; 37.5] min. For VOLT™-CE-Mark-study patients, procedure and BiB-dwell times were 72.5[67.3;85.0] and 25.0[21.0;28.2] min, compared with 48.5[36.5;59.0] and 23.5[18.3;36.3] min in non-study patients. All PVs were successfully isolated with 100% first-shot success using a median of 4 applications. Additional ablations included posterior wall(41%), anterior line(5%), CTI(3%), and SVC isolation(6%). One groin complication(1%) requirng intervention occured. Same-day discharge was conducted in 8%, limited primarily by institutional policy. Freedom from atrial tachyarrhythmia was 86% at median follow-up of 293[184;364]days.
conclusionThe BiB-PFA system enabled PVI with consistent first-shot success and a low rate of periprocedural complications. Follow-up available in a subset of patients suggested favorable early rhythm outcomes. TAKE HOME MESSAGE: • This study provides the first clinical experience with the BiB-PFA-system, characterizing procedural workflows and acute safety in routine practice • This study reports the first mid-term follow-up data for the BiB-PFA system, demonstrating an 86% freedom from atrial tachyarrhythmia after a 60-day blanking period at a median follow-up of 293 [184-364] days. • The integrated mapping-and-ablation design enabled efficient PVI with consistent first-shot success and short procedure times. • Ablation strategies beyond PVI-including posterior wall ablation, anterior line ablation, CTI ablation, and SVC isolation-were feasible and could be performed safely within the same workflow. • A low rate of periprocedural complications was observed in this cohort, including one vascular complication requiring intervention, supporting a favorable acute safety profile in a high-volume electrophysiology center.
Indexed as
Identifiers
42234368What OpenQuestion holds
Registered trials