Evidence map›Paper›PMID 42234305›Full record

ArticleBiomechanics and modeling in mechanobiology2026

A monolithic patient-specific 3D-0D model for In silico investigation of hemodynamics in patients with left ventricular assist devices.

Mia Bonini, Marc Hirschvogel, Michael Ferguson, Francis Pagani, Paul C Tang, David Nordsletten

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mia BoniniDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA. mbonini@umich.edu.
Marc HirschvogelDivision 2.2 Process Simulation, Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany.
Michael FergusonDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
Francis PaganiDepartment of Cardiac Surgery, University of Michigan, Ann Arbor, MI, USA.
Paul C TangDepartment of Cardiac Surgery, Mayo Clinic, Rochester, MN, USA.
David NordslettenDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present a fully coupled, patient-specific 3D-0D computational framework for hearts supported with left ventricular assist devices (LVAD) that enables controlled in silico experimentation. The approach monolithically integrates three-dimensional CFD of the left ventricle (LV), left atrium (LA), aortic root, and LVAD cannulae with a closed-loop 0D lumped parameter network of the full circulation. Mitral and aortic valve dynamics are governed by transvalvular pressure and flow with patient-specific regurgitant orifice areas, and the LVAD is represented via a pressure-flow (H-Q) relation. This manuscript provides the complete mathematical formulation, coupling strategy, and parameterization required to build a reproducible pipeline from dynamic CT, 2D transthoracic echocardiography, and right heart catheterization. This methodology is demonstrated in a patient under long-term support of LVAD and concomitant mitral and aortic regurgitation. The personalized, fully coupled 3D-0D models reproduced available clinical targets with a mean error of 8.6%, enabling controlled in silico interrogation of valve repair strategies. In the patient-specific state, simulated mitral and aortic regurgitant volumes were 6.6 and 6.5 mL per cycle, yielding a forward cardiac output of 3.16 L/min despite an LVAD flow of 3.7 L/min. In silico isolated mitral valve (MV) repair, isolated aortic valve (AV) repair, and combined MV+AV repair increased forward output to 3.41, 3.33, and 3.55 L/min, respectively; however, aortic valve opening and increased aortic pressure pulsatility (up to 38.9 vs. 13.5 mmHg) were observed only when MV repair was involved. These left-sided improvements propagated through the cardiopulmonary circulation, reducing pulmonary pressures and right ventricular loading, with the largest benefit observed following combined repair. We show that the modeling platform presented provides a powerful means to study mechanical circulatory support, enabling patient-specific evaluation of surgical interventions in patients with LVAD and delivering quantitative insight into clinically important metrics-such as aortic pulsatility, RV afterload, and chamber-level flow patterns.

Indexed as

Computer SimulationHeart-Assist DevicesHeart VentriclesHemodynamicsImaging, Three-DimensionalModels, CardiovascularPatient-Specific ModelingHumansComputational fluid dynamicsHemodynamic modelingLeft ventricle assist deviceLumped parameter modelingPatient-specific modeling

Identifiers

PMID42234305
PMCPMC13234087

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked