Evidence map›Paper›PMID 42234260›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2026

Comparison of the accuracy for cup positioning between portable inertial navigation systems and manual methods during total hip arthroplasty in the anterolateral supine position.

Yuichi Kuroda, Tomoyuki Kamenaga, Naoki Nakano, Masanori Tsubosaka, Tomoyuki Matsumoto, Ryosuke Kuroda, Shinya Hayashi

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuichi KurodaDepartment of Orthopaedics, Kobe University, Kobe, Japan. 0321yuichi0321@gmail.com.
Tomoyuki KamenagaDepartment of Orthopaedics, Kobe University, Kobe, Japan.
Naoki NakanoDepartment of Orthopaedics, Kobe University, Kobe, Japan.
Masanori TsubosakaDepartment of Orthopaedics, Kobe University, Kobe, Japan.
Tomoyuki MatsumotoDepartment of Orthopaedics, Kobe University, Kobe, Japan.
Ryosuke KurodaDepartment of Orthopaedics, Kobe University, Kobe, Japan.
Shinya HayashiDepartment of Orthopaedics, Kobe University, Kobe, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study primarily aimed to compare the accuracy of acetabular cup positioning between the portable inertial navigation system (INS) Navbit Sprint and the manual method during total hip arthroplasty (THA) using the same cup in the supine position. The second aim was to investigate patient factors associated with cup positioning accuracy for THA with a portable INS. MATERIALS AND

methodsThis study included 105 consecutive patients who underwent THA using a portable INS (n = 54) or manual methods (n = 51). The absolute difference between the target and postoperative angles, as determined by postoperative computed tomography data (placement error), was compared between the portable INS and manual method groups. The absolute value of the difference between the navigation and postoperative angles (measurement error) was also evaluated, and related factors were analyzed using multiple regression analysis.

resultsThe average placement error with the portable INS group was 3.6 ± 2.7° and 2.6 ± 2.5° for inclination and anteversion, respectively. For the manual method group, the absolute difference was 6.0 ± 4.0° and 4.5 ± 3.5° for inclination and anteversion, respectively. Significant differences were observed between groups. The average measurement error of the portable INS group was 2.5 ± 1.9° and 2.7 ± 2.2° for inclination and anteversion, respectively. The measurement error for inclination significantly correlated with the leg length discrepancy.

conclusionsCup positioning with the Navbit Sprint was significantly more accurate than the manual method during THA using the same cup in the anterolateral supine position. However, a significant leg length discrepancy could negatively impact the accuracy of cup positioning inclination.