Evidence map›Paper›PMID 42234205›Full record

ArticleClinical oral investigations2026

Accuracy and bias of high-frequency ultrasonography in measuring white spot lesion depth: an in-vitro comparison with micro-CT.

Taylor Toothman Sulkowski, Steven Makowka, Oliver D Kripfgans, William Tanberg, Stephen Warunek, Thikriat Al-Jewair

Abstract readComparative Study
In one paragraph

Article in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Taylor Toothman SulkowskiOrthodontist, private practice, Chapel Hill, NC, USA.
Steven MakowkaMaterials Testing Facility, State University of New York at Buffalo, Buffalo, NY, USA.
Oliver D KripfgansDepartment of Radiology and Biomedical Engineering, Medical School and College of Engineering, University of Michigan, Ann Arbor, MI, USA.
William TanbergDepartment of Biostatistics, School of Public Health and Health Professions, State University of New York at Buffalo, Buffalo, NY, USA.
Stephen WarunekDepartment of Orthodontics, School of Dental Medicine, State University of New York at Buffalo, 3435 Main Street, Buffalo, NY, 14214, USA.
Thikriat Al-JewairDepartment of Orthodontics, School of Dental Medicine, State University of New York at Buffalo, 3435 Main Street, Buffalo, NY, 14214, USA. thikriat@buffalo.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis in vitro study aimed to evaluate the accuracy and bias of Ultrasound (US) in measuring the depth of white spot lesions (WSLs), in comparison to micro-CT (µ-CT). MATERIALS AND

methodsThe study included 120 bovine maxillary incisors. Artificial WSLs were created on the facial surface of each incisor. Incisors were categorized into two groups, shallow WSLs and deep WSLs and subjected to 2-day and 4-day pH cycling protocols, respectively. All samples were imaged with both µ-CT and US using second harmonic imaging at 12/24 MHz. WSL depth was measured and the average calculated. Enamel thickness was assessed on the µ-CT images using the same methodology.

resultsMean lesion depths in the shallow WSLs group were 138.3±17.8 μm (µ-CT) and 169.2 ± 37.8 μm (US), while in the deep WSLs group, depths averaged 299.9 ± 47.7 μm (µ-CT) and 309.3 ± 75.7 μm (US). The absolute mean differences between µ-CT and US were significantly different from zero (p < 0.001). US consistently overestimated lesion depth compared to µ-CT in both groups, with a significant difference in the shallow WSLs group (p < 0.001).

conclusionsUS demonstrates lower accuracy than µ-CT in measuring WSL depth, consistently overestimating lesion depths, particularly in the shallow WSLs group. CLINICAL RELEVANCE: The ability of a diagnostic method to measure WSLs of varying depths is clinically important, as treatment efficacy depends on lesion depth and the extent of enamel demineralization. US in non-invasive and demonstrates potential for clinical use; however, further validation is required before it can be reliably applied to the clinical assessment of WSL depth. Clinicians must also consider practical factors such as equipment cost and size, the need for coupling materials, and requirements for operator training and calibration.

Indexed as

Dental CariesX-Ray MicrotomographyAnimalsCattleDental EnamelIncisorIn Vitro TechniquesReproducibility of ResultsUltrasonographyDemineralizationDepthMicro-CTUltrasoundWhite spot lesions

Identifiers

PMID42234205
PMCPMC13234065

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.