Evidence map›Paper›PMID 42232783›Full record

ArticleJHLT open2026

Comparative outcomes of intra-aortic balloon pump versus impella in non-myocardial infarction cardiogenic shock: A National Inpatient Sample Database analysis.

Omar Khalil, Arwa Saed Aldien, Peng Cai, Aditi Patel, Racha Ghoussaini, Hussein Krayem, Qi Liu, Michael C Kontos, Charlotte Roberts, Zubair Hashmi and 4 more

Abstract read
In one paragraph

Article in JHLT open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Omar KhalilDepartment of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Arwa Saed AldienDepartment of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Peng CaiDepartment of Mathematical Sciences Worcester Polytechnic Institute, Worcester, MA.
Aditi PatelDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Racha GhoussainiDepartment of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Hussein KrayemDepartment of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Qi LiuWafic Said Molecular Cardiology Research Laboratory, The Texas Heart Institute, Houston, TX.
Michael C KontosDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Charlotte RobertsDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Zubair HashmiDivision of Cardiac Surgery, Pauley Heart Center Virginia Commonwealth University, Richmond, VA.
Richard CookeDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Krishnasree RaoDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Keyur B ShahDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.
Pengyang LiDivision of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Intra-aortic balloon pumps (IABPs) and percutaneous left ventricular assist devices (pLVADs; Impella) are used to stabilize patients with cardiogenic shock (CS). While recent evidence supports their usefulness in myocardial infarction (MI)-related CS, data on non-MI CS, particularly regarding newer Impella models, remain limited. We compared outcomes associated with IABP versus various Impella devices in non-MI CS. Methods: We retrospectively analyzed National Inpatient Sample (NIS) data from 2016 to 2022 to identify patients with non-MI CS who received IABP, Impella 2.5/CP, or Impella 5.0/LD/5.5. Outcomes explored were in-hospital mortality, rates of orthotopic heart transplant (OHT) and durable left ventricular assist device (LVAD) implantation, blood transfusion requirements, length of stay, and total hospital charges. Results: Among patients with non-MI CS, Impella 5.0/LD/5.5 use was associated with lower in-hospital mortality (8.2% vs 14.9%, Conclusions: In non-MI CS, the high-flow Impella 5.0/LD/5.5, but not the low-flow Impella 2.5/CP, was associated with better survival and higher rates of advanced therapies than IABP, albeit at the expense of greater transfusion requirements, longer hospitalization, and greater resource utilization.

Indexed as

cardiogenic shockImpella 2.5/CPImpella 5.0/LD/5.5intra-aortic balloon pumpmortality

Identifiers

PMID42232783
PMCPMC13223703

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.