Validation of a Low-Cost Handheld Dynamometer Against a Standard Device for Handgrip Strength Assessment in Stable Outpatients with Cirrhosis.
Article in Journal of frailty, sarcopenia and falls, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The role of low muscle strength in predicting mortality in patients with liver cirrhosis and hepatocellular carcinoma.Internal and emergency medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: Handgrip strength (HGS) is a key metric in cirrhosis. Multiple devices exist for HGS measurement, with gender specific cut-offs being established. However, the cut-offs do not account for potential differences between devices. We assessed the performance of the Camry EH101® handgrip dynamometer against the gold-standard Jamar® dynamometer in cirrhosis. Methods: This prospective observational study enrolled stable outpatients with cirrhosis (≥ 18 years). Baseline demographic and biochemical indices were assessed. HGS testing was performed by two dynamometers (Camry EH101® and Jamar®) and evaluated for correlation, systematic differences, and level of agreement. Results: 76 stable outpatients [48.1±12.1 years, 50 (65.7%) were males, MASLD, 77.7%] were enrolled. The overall right HGS by Jamar® and Camry EH101® dynamometers in males was 31.3±6 Kg and 25.6±7.3Kg, respectively, while it was 19.4±4.7 and15.0±3.4 in females. The correlation coefficient for right- and left-hand measurements was 0.82 (0.72-0.88) and 0.81 (0.72-0.88), respectively. Regression analysis showed no significant deviation from linearity. Bland-Altman plots for levels of agreement showed most values falling within the +/-1.96 SD range. However, there were outliers overall, representing a modest level of agreement. Conclusion: While the Jamar® handgrip dynamometer remains the gold standard, alternatives like the Camry EH101® dynamometer show good correlation and modest agreement.