ArticleiScience2026
An approach for estimating thermoelectric module equivalent properties by thermal resistance and numerical modeling.
Article in iScience, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Thermoelectric material properties are crucial for simulating thermoelectric modules (TEMs); yet, determining them requires complex and costly experiments due to temperature-dependent behavior and parasitic losses. This work proposes an approach for estimating TEM's equivalent properties from its output characteristics using thermal resistance (TRM) and numerical simulation modeling (NSM) accessibly, cost-effectively, and time-efficiently. Sensitivity analysis and cross-module validation confirm the method's reliability. The obtained equivalent property sets enable accurate prediction of TEM's output characteristics for the TRM and NSM compared with manufacturer data, with deviations of open-circuit voltage, maximum power, and conversion rate of 0.87%, 2.53%, and 3.07% for TRM, and 0.91%, 2.51%, and 3.24% for NSM, respectively. This finding implies that a TRM of TEMs can replace NSM in large-scale simulations, saving resources while ensuring accuracy. The proposed approach makes determining TEM properties less challenging; also, the equivalent properties reduce computational efforts required for simulating the thermoelectric generator system characteristics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.