Evidence map›Paper›PMID 42231164›Full record

Observational studyBMC anesthesiology2026

Effect of 10 cm H₂O positive end-expiratory pressure on right internal jugular vein cross-sectional area in obese patients under general anesthesia: a prospective observational study.

Xiaofan Zheng, Xiaoqiong Cao, Shiwen Shen, Dongliang Pei

Abstract readObservational Study
In one paragraph

Observational study in BMC anesthesiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xiaofan Zheng *Department of Anesthesiology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Xiaoqiong Cao *Department of Anesthesiology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Shiwen Shen *Department of Emergency Medicine, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Dongliang PeiDepartment of Anesthesiology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. ketpayne@foxmail.com.

Funding

the Research Fund of Shanghai Tongren Hospital, Shanghai Jiao Tong University School of Medicine TRYJ2024LC17The Shanghai Health System Key Discipline Project 2024ZDXK0055
6 · The paper itself

Abstract

backgroundObesity can complicate central venous catheterization by increasing skin-to-vessel depth and impairing ultrasound visualization. Optimizing internal jugular vein (IJV) cross-sectional area (CSA) is a key strategy to facilitate cannulation. Positive end-expiratory pressure (PEEP) is known to promote IJV distension in non-obese individuals and constitutes a component of lung-protective ventilation in obese patients; however, its efficacy for IJV distension and hemodynamic safety in the obese population remain uncertain. This study investigated the association between 10 cm H₂O PEEP and right IJV CSA, as well as the hemodynamic tolerability of this intervention, in obese patients under general anesthesia.

methodsThis prospective observational study enrolled 40 adult patients with body mass index (BMI) > 30 kg/m² undergoing elective surgery at Tongren Hospital, Shanghai Jiao Tong University School of Medicine between June and October 2025. Following standardized anesthesia induction and hemodynamic stabilization, each patient underwent ultrasound measurement of right IJV CSA at both zero end-expiratory pressure (ZEEP) and PEEP 10 cm H₂O in a randomized, self-controlled design. The outcome assessor was blinded to PEEP levels. Mean arterial pressure (MAP) and heart rate (HR) were recorded concurrently. The primary outcome was the difference in IJV CSA between ZEEP and PEEP 10 cm H₂O. Paired Student's t-tests and Wilcoxon signed-rank tests were used as appropriate, and multivariable linear regression explored factors associated with the change in CSA (ΔCSA).

resultsAll 40 patients (median BMI 32.19 [IQR 31.17-33.59] kg/m²; 52.5% male) completed the study with no dropouts or missing data. PEEP 10 cm H₂O was associated with a significant increase in right IJV CSA from 1.33 ± 0.48 cm² to 1.62 ± 0.63 cm² (mean paired difference [ΔCSA] 0.28 ± 0.42 cm², 95% CI 0.15 to 0.42, p < 0.001), representing a relative increase of approximately 21%. MAP showed a modest decrease (median paired difference [ΔMAP] - 7 mmHg, IQR - 13.25 to -2.42, p < 0.001), and HR decreased correspondingly (mean paired difference [ΔHR] 5.68 ± 7.40 bpm, 95% CI 3.30 to 8.04, p < 0.001). No patient experienced severe hypotension (MAP < 65 mmHg) or required vasopressor support. Exploratory multivariable regression did not identify significant associations between ΔCSA and BMI, neck circumference, age, sex, or ASA status (all p > 0.05); however, statistical power was limited by the sample size.

conclusionsThe application of 10 cm H₂O PEEP was associated with increased right IJV CSA in moderately obese patients under general anesthesia. This maneuver was well tolerated with clinically acceptable hemodynamic changes in this specific cohort.

trial registrationChinese Clinical Trial Registry, ChiCTR2400091755.

Indexed as

Anesthesia, GeneralJugular VeinsObesityPositive-Pressure RespirationAdultAgedCatheterization, Central VenousFemaleHemodynamicsHumansMaleMiddle AgedProspective StudiesUltrasonographyCross-sectional areaInternal jugular veinObesityPositive end-expiratory pressure

Identifiers

PMID42231164
PMCPMC13449495

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.