ArticleScientific reports2026
Design of an AI-based security anomaly detection system for IoT terminals based on the ViT-transformer fusion model.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The deep penetration of IoT terminals in water systems, healthcare, transportation, and other fields has exacerbated security threats such as cyber-physical attacks and traffic anomalies. However, traditional anomaly detection methods have limitations such as dependence on labeled data, weak generalization ability, high resource consumption, and prominent privacy risks. Although Vision Transformer (ViT) has the advantage of capturing global features, it is difficult to directly adapt to resource-constrained IoT terminals. In existing research, hybrid deep learning models have improved detection accuracy, but lightweight ViT fusion models lack terminal adaptability and multi-modal data fusion applications are scarce. The balance between dynamic scheduling and privacy protection in end-edge-cloud collaboration still needs to be broken through. To address the above issues, this paper proposes an IoT terminal AI security anomaly detection system based on the ViT-Transformer fusion model: adopting a three-level end-edge-cloud collaborative architecture, integrating multi-modal data such as network traffic, sensor timing, and side channel signals, and achieving cross-modal feature fusion through tokenization; combining pruning, distillation, and quantization optimization strategies to increase the model compression ratio to 70%; introducing Elliptic Curve Certificateless Encryption (CL-PKE) and Batch Listing Signature (BLS) batch authentication to ensure data security, and using federated learning to aggregate edge model updates and optimize global performance. Experiments were conducted on public datasets such as IoT-23 and UCI, as well as a self-made testbed. The results show that the model achieves an accuracy of 89.2% and an F1-score of 0.87 in multi-modal anomaly detection, with a terminal inference delay of 90ms and a memory footprint of 30MB, adapting to low-computing devices such as RPi4B and Arduino; CL-PKE resists brute force attacks for 5.2e6 seconds, and batch authentication for 100 terminals takes only 75ms; it exhibits excellent generalization across smart home, industrial IoT, and other scenarios, with a defense success rate of 85.3% against FGSM attacks. This study effectively addresses the resource bottleneck and security pain points of existing methods, providing an efficient and reliable technical solution for IoT terminal security.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.