ArticleAnimal bioscience2026
Beef Color Standard, including marbled Wagyu beef, determined using a portable near-infrared optical fiber spectrometer.
Article in Animal bioscience, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe purpose of this study was to see if a portable near-infrared optical fiber spectrometer with a wavelength range of 700-1,050 nm could objectively predict the Beef Color Standard (BCS), which is visually evaluated during beef carcass grading.
methodsA total of 1,077 carcasses were procured from Japanese Black (JB) Wagyu (n = 534), crossbred (F1) (n = 367), and dairy cows (n = 176) shipped to meat markets. The cut surface between the sixth and seventh ribs was visually evaluated by grading members using the BCS. In addition, a near-infrared optical fiber spectrometer was applied to the cut surface to obtain the reflectance spectrum. Using data from 827 carcasses, a calibration model was established through a partial least squares regression analysis using the BCS value as the objective variable, while the optical data following quadratic differential processing as the explanatory variable. Using data from 250 additional animals, the calibration model and predicted BCS values were verified for accuracy.
resultsThe calibration model exhibited a high correlation coefficient of 0.83 and a standard error of calibration of 0.70. The predicted BCS by near-infrared evaluation rarely differed significantly from the actual BCS, and the difference was roughly distributed in the range of ±1. For verifying the accuracy of our calibration model, the correlation coefficient between the actual BCS and the predicted value for the validation sample was 0.75, and the standard error of prediction was 0.71. The probability that the error between the measured and optically predicted BCS values in the validation samples was within ±1 and ±0 was 97.6% and 54.4%, respectively.
conclusionUsing a portable near-infrared fiber optic spectrometer, we demonstrated that the BCS value of beef carcasses, particularly marbled Wagyu beef in meat markets, can be objectively evaluated with relatively high accuracy.