Evidence map›Paper›PMID 42225861›Full record

ArticleScientific reports2026

A self-supervised depth-aware method for pose optimization in hybrid bronchoscopic navigation.

Xiaoyue Liu, Xiang Deng, Tian Xu, Tianyuan Gan, Chongan Zhang, Peng Wang, Hong Zhang, Xuesong Ye

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xiaoyue Liu *Biosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Xiang Deng *Biosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Tian XuBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Tianyuan GanBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Chongan ZhangBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Peng WangBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Hong ZhangBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China.
Xuesong YeBiosensor National Special Laboratory,College of Biomedical Engineering and Instrument Science, Zhejiang University, 38 Zheda Road, Hangzhou, Zhejiang Province, 310027, P.R. China. yexuesong@zju.edu.cn.

Funding

the Cross-disciplinary Collaboration Original Project Cultivation Funding Program of Department of General Surgery Sir Run‑Run Shaw Hospital School of Medicine, and Department of Biomedical Engineering, Zhejiang University Grant Nos. 114105-I22402the Key Research and Development Plan of Zhejiang Province Grant No. 2023C03094,2024C03008
6 · The paper itself

Abstract

Pose optimization is essential for aligning bronchoscopic views with preoperative CT scans in hybrid vision-electromagnetic navigation systems. It helps eliminate the discrepancies between the virtual and actual bronchoscope positions in the navigation process. However, a large modality gap between virtual (CT-rendered) and real bronchoscopic scenes introduces appearance and scale ambiguities that hinder robust pose estimation. This paper presents a self-supervised pose estimation method, named Depth-aware Attention Pose Network (DaAPNet). In particular, DaAPNet integrates a Depth-aware Attention module to resolve structural ambiguities by leveraging depth information to guide attention towards geometrically consistent regions, such as bronchial bifurcations. To further suppress unreliable appearance cues, an entropy-based uncertainty-weighted masking mechanism dynamically attenuates low-confidence regions in the attention process. A dedicated scale prediction module further enforces geometric consistency to recover cross-modality scale factor, while a pose consistency loss promotes temporal stability. Extensive experiments on virtual and phantom bronchus datasets show that DaAPNet achieves improved estimated performance. Qualitative results indicate that it effectively mitigates appearance ambiguity by capturing clear representations of bronchial bifurcations. Quantitatively, it restores scale consistency along the forward direction, reducing translation error by 35.99%.

Indexed as

BronchoscopyImage Processing, Computer-AssistedAlgorithmsBronchiHumansPhantoms, ImagingTomography, X-Ray ComputedDepth-aware attentionHybrid navigationPose optimizationSelf-supervised learning

Identifiers

PMID42225861
PMCPMC13458055

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.