Evidence map›Paper›PMID 42224726›Full record

ArticleJournal of neurosurgery. Case lessons2026

Displacement of synthetic cranioplasty implant due to mechanical failure of titanium fixation plating: illustrative case.

Graham A Branscom, Evan M Ren, Michael B Lemonick, Bahie Ezzat, Ziad Rifi, Shahram Majidi, Christopher P Kellner, Tomoyoshi Shigematsu

Abstract read
In one paragraph

Article in Journal of neurosurgery. Case lessons, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Graham A BranscomDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0009-0000-3144-9191
Evan M RenDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.
Michael B LemonickDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.
Bahie EzzatDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0000-0001-9729-9122
Ziad RifiDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0000-0003-3545-796X
Shahram MajidiDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0000-0003-2971-6216
Christopher P KellnerDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0000-0003-4604-8205
Tomoyoshi ShigematsuDepartment of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York.ORCID 0000-0003-3463-0222

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCranioplasty is a common procedure following decompressive craniectomy for traumatic brain injury or stroke, among other reasons, in order to repair a skull defect. Cranioplasty failure is an infrequent occurrence, but in the case of synthetic implants, it is usually caused by infection and incorrect sizing. However, trauma-induced displacement, breakage, and deformities of cranioplasty implants are less common. OBSERVATIONS: The authors present a unique case of a cranioplasty failure due to displacement of a polyetheretherketone (PEEK) implant secondary to catastrophic breakage of the titanium fixation plates. The cause of displacement is unknown but is suspected to be trauma. A subsequent review of the literature contextualizes common reasons for failure among synthetic implants and suggests that fracture of synthetic implants or their fixation plates is extremely rare. LESSONS: The displacement of a PEEK cranioplasty implant due to breakage of titanium fixation plates is a rare, albeit possible, complication of this neurosurgical procedure. Lifestyle modifications are paramount to reduce trauma risk and resultant cranioplasty failure. The addition of miniplates may also reduce implant displacement risk. Finally, since rates of failure differ by material, careful consideration of the type of material used for the implant should be incorporated into neurosurgical planning. https://thejns.org/doi/10.3171/CASE2694.

Indexed as

case reportcranioplasty failurePEEK implanttitanium

Identifiers

PMID42224726
PMCPMC13224980

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.