Evidence map›Paper›PMID 42223905›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Blob representation of robotic surgical scenes for position-aware video generation.

Laurent Mennillo, Chen Katzir, Runlong He, Dimitrios Anastasiou, Danail Stoyanov, Evangelos B Mazomenos

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Laurent Mennillo *Department of Medical Physics & Biomedical Engineering, University College London, London, UK. l.mennillo@ucl.ac.uk.ORCID http://orcid.org/0000-0001-5220-6631
Chen Katzir *Department of Medical Physics & Biomedical Engineering, University College London, London, UK.
Runlong HeDepartment of Medical Physics & Biomedical Engineering, University College London, London, UK.ORCID https://orcid.org/0009-0003-9252-1662
Dimitrios AnastasiouDepartment of Medical Physics & Biomedical Engineering, University College London, London, UK.
Danail StoyanovDepartment of Computer Science, University College London, London, UK.ORCID https://orcid.org/0000-0002-0980-3227
Evangelos B MazomenosDepartment of Medical Physics & Biomedical Engineering, University College London, London, UK. e.mazomenos@ucl.ac.uk.ORCID https://orcid.org/0000-0003-0357-5996

Funding

Engineering and Physical Sciences Research Council EP/Z534754/1UK Research and Innovation UKRI145University College London DTP EP/T517793/1
6 · The paper itself

Abstract

purposeSynthetic video generation offers substantial promise for AI development in robot-assisted minimally invasive surgery (RMIS), addressing the limited availability of annotated datasets. We present a novel approach for realistic and controllable RMIS video generation, leveraging robot kinematics to constrain the spatial position of the surgical tools in the generated frames.

methodsOur architecture uses a Blob Generation module that transforms 3D kinematic data into rigid 2D blob representations for spatial conditioning of a Frame Generation module using an encoder-decoder with temporal retention.

resultsQuantitative and qualitative evaluations on the suturing task of the JIGSAWS benchmark dataset demonstrate that our approach enhances both video fidelity and positional accuracy of the surgical tools over long sequences. Blob spatial accuracy against pseudo-ground-truth labels yields average bounding box and mask Dice scores of 0.78 and 0.71, respectively, while video synthesis improves on average by 2% and 5% for SSIM and 4% and 9% for PSNR, while LPIPS reduces by 9% and 20%, compared to baseline state-of-the-art auto-regressive approaches for frames generated at

conclusionThese results validate the potential of blob representation for position-aware, realistic video generation in RMIS. Synthesized data can augment available datasets, benefiting downstream tasks such as instrument tracking, workflow/skill analysis and robotic automation.

Indexed as

Imaging, Three-DimensionalMinimally Invasive Surgical ProceduresRobotic Surgical ProceduresVideo RecordingBiomechanical PhenomenaHumansComputer vision for surgical roboticscontrollable video generation

Identifiers

PMID42223905
PMCPMC13553727

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.