Evidence map›Paper›PMID 42223709›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2026

CT-based quantitative assessment of talar neck geometry: development of a standardized protocol and reliability analysis.

Siddhartha Sharma, Pratik Rathod, Karan Jindal, Mahesh Prakash, Stefan Rammelt, Mandeep Dhillon

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Siddhartha SharmaFoot and Ankle Biomechanics, Experimentation and Research Laboratory, Department of Orthopedics, Post Graduate Institute of Medical Education and Research, Chandigarh, India. sids82@gmail.com.
Pratik RathodDepartment of Orthopedics, Preethi Hospital, Madurai, India.
Karan JindalDepartment of Orthopedics, Max Super Speciality Hospital, Chandigarh, India.
Mahesh PrakashDepartment of Radiodiagnosis, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Stefan RammeltFoot and Ankle Center, Department of Orthopedic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany.
Mandeep DhillonDepartment of Orthopedics, Fortis Hospital, Mohali, India.

Funding

Indian Council of Medical Research IIRP-2023-7083
6 · The paper itself

Abstract

objectiveTo define reproducible computed tomography (CT)-based parameters for quantifying talar neck geometry and to evaluate their inter- and intra-observer reliability. MATERIALS AND

methodsThirty-five CT studies of adult feet without talar pathology were randomly selected from a prospectively maintained database. Multiplanar reconstructions were standardized along the talar axes to define reference planes. Five morphometric parameters were measured: declination angle, inclination angle, torsion angle, and medial and lateral talar neck lengths. Two fellowship-trained orthopedic surgeons and one musculoskeletal radiologist independently performed all measurements twice, four weeks apart, using DICOM viewer software. Inter- and intra-observer reliability were calculated using two-way random effects intraclass correlation coefficients (ICC).

resultsAll parameters were identifiable and measurable on the standardized CT planes across all studies. Inter-observer reliability was excellent for inclination angle (ICC 0.92, 95% CI 0.87-0.96) and good for declination angle (ICC 0.81, 95% CI 0.69-0.89); torsion angle showed poor reliability (ICC 0.41, 95% CI 0.20-0.61). Medial and lateral neck lengths demonstrated good reliability (ICC 0.77-0.83). Intra-observer reliability across observers was good to excellent (ICC > 0.80 for all parameters except torsion).

conclusionWe have established a standardized CT-based protocol for assessing talar neck geometry with good-to-excellent reliability for most parameters. The proposed framework enables consistent quantification of talar neck alignment and could be potentially useful for facilitating evaluation of fracture reduction and correction planning in talar malunions.

Indexed as

TalusTomography, X-Ray ComputedAdultFemaleHumansMaleMiddle AgedObserver VariationReproducibility of ResultsComputed tomographyFracture reductionMorphometryReliabilityTalar neckTalus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.