Evidence map›Paper›PMID 42220334›Full record

ArticleSensors and actuators. B, Chemical2025

Portable hepatitis C virus RNA extraction and stabilization using low-cost lab-on-a-chip style components with shelf stable reagents.

Sarah Hernandez, Dhruv Miglani, Jayden Kimbro, Alessandra Luna, Heather Jones, Benjamin A Pinsky, Jesse J Waggoner, David R Myers

Abstract read
In one paragraph

Article in Sensors and actuators. B, Chemical, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Nipah virus molecular detection from whole blood and respiratory swabs in a rapid field-ready protocol.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sarah HernandezEmory University Department of Medicine, Division of Infectious Diseases, 100 Woodruff Circle, Atlanta, Georgia, 30322, USA.
Dhruv MiglaniWallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, 1760 Haygood Dr, Atlanta, Georgia, 30322, USA.
Jayden KimbroEmory University Department of Medicine, Division of Infectious Diseases, 100 Woodruff Circle, Atlanta, Georgia, 30322, USA.
Alessandra LunaWallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, 1760 Haygood Dr, Atlanta, Georgia, 30322, USA.
Heather JonesEmory Medical Laboratories, Emory Healthcare, 1525 Clifton Road NE, Atlanta, Georgia, 30322, USA.
Benjamin A PinskyStanford University School of Medicine, Department of Pathology, Lane Building, L235, 300 Pasteur Drive, Stanford, CA, 94305, USA.
Jesse J WaggonerEmory University Department of Medicine, Division of Infectious Diseases, 100 Woodruff Circle, Atlanta, Georgia, 30322, USA.
David R MyersWallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, 1760 Haygood Dr, Atlanta, Georgia, 30322, USA.

Funding

Integrating low-cost and versatile technologies to achieve colorimetric HCV and HIV detection from whole bloodR01AI180093 · NIAID · EMORY UNIVERSITY · PI Matthew Collins, David Richard Myers · 2024 to 2026
$2.1M
NIAID NIH HHS R01 AI180093
6 · The paper itself

Abstract

Molecular tests offer a powerful approach to diagnosing numerous diseases and, due to advances in lab-on-a-chip technologies, have the potential to be used in the field and at the bedside. However, there is still a need for portable technologies that help isolate nucleic acids from their associated sample for testing. Previously, our groups developed an RNA extraction and stabilization (RNAES) protocol that utilized novel shelf stable reagents to extract, isolate, and store nucleic acids on membranes at ambient temperature. Building on these results, we have created RNAES kits with reductionist, 3D-printed, lab-on-a-chip style parts that enable field isolation of RNA without external equipment or power. Our kits feature three components, a lysis sphere, a capillary-wicking based cartridge for RNA isolation, as well as a drying & storage tube that stabilizes RNA for ambient temperature shipping. Using our kit, a user can process a 25 μL sample of serum or plasma within 15 minutes, including a 10-minute incubation time. Noting that hepatitis C virus (HCV) can be cured when detected, we use our RNAES kit in combination with a new real-time RT-PCR to detect HCV. Our data on 98 clinical samples and four contrived whole blood samples show comparable RNA detection and quantified viral loads following extraction with our RNAES kit or a commercial system. Our approach also provided the additional benefit of stabilizing viral RNA for storage at ambient temperatures as lysate, for up to 7 days, or on dried membranes in storage tubes, for at least 30 days.

Indexed as

ExtractionHepatitis CIsolationRNAStabilization

Identifiers

PMID42220334
PMCPMC13218640

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.