ArticleJournal of applied clinical medical physics2026
Three-dimensional Cherenkov emission surface mapping into the patient coordinate system for spatial delivery verification in EBRT.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundCherenkov imaging provides the ability to visualize beam delivery during radiation therapy treatments in real-time informing the therapy team about possible deviations from the treatment plan. Current clinical practice with Cherenkov imaging relies on the real-time view and post-treatment qualitative assessment of Cherenkov images by therapists, physicists and clinicians who may then perform secondary treatment checks. PURPOSE: While Cherenkov images provide new insights into beam location, the limitation is that quantifying the observed deviation is difficult due to the lack of spatial registration of the Cherenkov emission in patient's coordinate space. This work addresses this problem with the first fusion of Cherenkov images with the three-dimensional patient surface to enable quantitative spatial beam verification in patient coordinate space. By combining multiple camera viewpoints with CT-sim derived surface coordinates, this system is capable of generating virtual beam's eye view images for objective measurement of beam delivery deviations on patient surfaces. This approach enables automated error detection thresholds and represents the first step toward real-time, quantitative optical treatment verification and dosimetry.
methodsCherenkov images from multiple geometrically calibrated cameras were projected onto Computed Tomography (CT) surface datasets to provide a Cherenkov surface image map on the patient. A raycasting algorithm was utilized to virtually map the Cherenkov surface image into the beam's eye view. To test the ability to quantitatively measure beam versus patient surface deviations from the virtual beam's eye view, a series of 10 × 10 cm
resultsIterative Closest Point algorithms achieved an average x and y accuracy of 0.5 ± 0.2 mm and 0.3 ± 0.2 mm for the flat phantom and 0.5 mm ± 0.7 mm and 0.3 mm ± 0.2 mm for the anthropomorphic torso phantom. Camera projection error adds up to an additional 0.9 mm of error.
conclusionMulti-view surface mapping of Cherenkov images onto the patient surface mesh enabled quantitative assessment of beam versus topology shifts between fractions, using the Cherenkov emission outline as a beam extent surrogate. We demonstrated the utility and metrics of Cherenkov 3D mapping towards future applications utilizing daily or real-time surfaces obtained from, for example, cone-beam CT or surface-guided radiotherapy (SGRT) systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.