ArticleJournal of applied clinical medical physics2026
Field output correction factors and perturbation factor analysis for novel SunSILICON and SunSILICON P silicon diode detectors.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Clinical application of an unshielded silicon diode detector for relative electron beam dosimetry.Journal of applied clinical medical physics · 2026Article
- Clinical evaluation of two new unshielded and shielded silicon diode detectors in external photon beam radiation therapy: SunSILICON and SunSILICON P.Journal of applied clinical medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundField output factor measurements of clinical linear accelerators require detector-specific corrections, due to the introduction of fluence perturbation effects by non-water-equivalent components of applied detectors. PURPOSE: This study aims to determine field output correction factors for novel shielded and unshielded silicon diode detectors in high energy photon fields. Special emphasis is placed on understanding the influence of perturbation factors and evaluating the suitability of these detectors across a wide range of field sizes.
methodsField output correction factors for the silicon diodes SunSILICON and SunSILICON P were determined through experimental measurements conducted at four distinct sites. Monte Carlo-based models of the diode detectors were developed to calculate field output correction factors using the EGSnrc code system. In addition, these silicon diode models enabled a detailed analysis of perturbation factors for field sizes from 0.6 cm up to 40 cm.
resultsExperimentally determined and Monte Carlo calculated field output correction factors are in good agreement for the detectors investigated. The perturbation factor analysis demonstrated a strong field size dependence of the fluence perturbation factor for silicon.
conclusionThis is the first study to systematically characterize the SunSILICON diode detector family using both simulation and measurement. The findings confirm that both shielded and unshielded designs are suitable for clinical dosimetry in photon beams, requiring only minor corrections. The shielding of the SunSILICON P diode enables accurate field output factor measurements across a broad range of field sizes, establishing its utility in modern radiotherapy applications.