Trial reportJournal of applied clinical medical physics2026
Investigating Setup Error Differences between Conventional and Ultra-Hypofractionated Whole Pelvis Radiation Therapy: A Secondary Analysis from the HOPE Randomized Clinical Trial.
Trial report in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04197141 (Is Hypofractionated Whole-Pelvis Radiotherapy), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Is Hypofractionated Whole-Pelvis Radiotherapy (WPRT) as Well Tolerated as Conventionally-Fractionated WPRT in Prostate Cancer Patients? (HOPE-Trial)
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
introductionThe multi-institutional HOPE trial (NCT04197141) compared conventional (25 fractions over 5 weeks) to ultra-hypofractionated (5 fractions over 1.5 weeks) whole pelvis radiotherapy for unfavorable intermediate and high/very high-risk prostate cancer patients treated with brachytherapy boost. Within this randomized controlled trial, we investigated setup errors for clinical target volumes corresponding to the prostate (CTVp) and nodes (CTVn).
methodsFifty-four patients treated within a single institution were analyzed, with 28 treated on the ultra-hypofractionated arm and 26 on the conventional fractionation arm. Prior to treatment, three fiducial markers were implanted into the prostate for daily cone-beam computed tomography (CBCT) matching. All plans were delivered using volumetric modulated arc therapy with a uniform 6-mm PTV margin. For all treatment fractions, average fiducial matching errors were measured for CTVp, while errors to CTVn were determined based on the difference between the treatment position and an automatic match to bone. Asymmetric PTV margins to account for prostatic and nodal setup errors were calculated using the van Herk formalism.
resultsMedian (interquartile range [IQR]) 3D errors for CTVp were 1.4 (0.8-2.5) mm for conventional versus 1.2 (0.7-1.9) mm for the ultra-hypofractionatated arms (p = 0.013), while for CTVn they were 2.8 (1.6-4.2) mm and 2.9 (2.2-4.4) mm, respectively (p = 0.07). Between arms, statistically significant differences in setup errors were noted in all directions for CTVp and in the anterior-posterior direction for CTVn (p < 0.05). To account for setup error, the required PTV margins in the anterior-posterior/superior-inferior/lateral directions were 2.8/3.8/0.8 and 2.7/3.0/1.0 mm for conventional and ultra-hypofractionated treatments, respectively; for elective nodes, margins were 5.4/4.4/0.7 and 5.7/4.9/1.0 mm, respectively.
conclusionsThe 6-mm PTV margin around the CTVn is appropriate to account for residual setup error while the margin around the CTVp could be reduced, assuming other sources of error are controlled. The residual 3D errors for the prostate were statistically significantly smaller in the ultra-fractionated regimen, which was potentially due to longer image matching times and/or the higher percentage of patients treated with a 6-DOF couch in that arm. However, this came at the expense of slightly larger nodal PTV margins in the ultra-hypofractionated arm. These findings highlight the need for individual centers to independently quantify their treatment uncertainties, as measurable differences were observed between treatment arms despite identical image guidance protocols.