Bench testing a contact sensing tracheal tube for monitoring the cuff-trachea interface.

Tamaralayefa B Agbiki, Sandor Erdody, Ricardo Correia, Sergiy Korposh, David W Hewson, Andrew M Norris, Barrie R Hayes-Gill, Stephen P Morgan

Abstract read
In one paragraph

Article in BMC biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tamaralayefa B AgbikiOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Sandor ErdodyOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Ricardo CorreiaOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Sergiy KorposhOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
David W HewsonAnaesthesia and Critical Care, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK.
Andrew M NorrisMedical Photonics Ltd, Nottingham, UK.
Barrie R Hayes-GillOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Stephen P MorganOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK. steve.morgan@nottingham.ac.uk.

Funding

Medical Research Council MR/R025266/1
6 · The paper itself

Abstract

Cuffed tracheal tubes enable a secure airway during mechanical ventilation; however, improper cuff inflation can lead to complications such as inspiratory gas leaks, pulmonary ingress of orogastric secretions, or tracheal injury. This study explores a sensor-based approach to optimise cuff inflation using fibre Bragg grating (FBG) optical sensors embedded within the cuff to detect contact with the tracheal wall. Testing was conducted on multiple trachea models, including cylindrical and bio-inspired models, as well as ex vivo porcine trachea samples, to assess cuff-trachea contact. Seal performance was evaluated at both standard inflation pressures and contact-guided inflation pressures. The contact-sensing tracheal tube successfully detected cuff-trachea contact in all models and ex vivo samples tested. Seal tests showed that larger diameter tracheal models exhibited lower leakage rates at contact-guided inflation pressures compared with standard inflation, indicating improved sealing. In contrast, smaller diameter models showed higher leakage rates at contact-guided pressures due to cuff folding, which formed leakage pathways. These results demonstrate that contact sensing improved cuff performance in larger tracheal models by enhancing sealing effectiveness. The contact-sensing tracheal tube differentiated tracheal model sizes, indicating potential for personalised cuff inflation to accommodate variations in tracheal size and shape. Future work will focus on further sensor miniaturisation and integration within lower-volume cuffs to enable effective contact sensing across a wider range of tracheal geometries and support translation to in vivo use.

Indexed as

Cuff monitoringOptical fibresSensorsTracheal intubationTracheal seal testing