Observational studyCritical care (London, England)2026
Electrical impedance tomography-derived flow index during spontaneous breathing trial stratifies the risk of reintubation within 48 h after extubation.
Observational study in Critical care (London, England), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06876792 (Electrical Impedance Tomography-derived Flow Index During Spontaneous Breathing Trial Stratifies the Risk of Reintubation Within 48 h After Extubation), which is not on this map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Electrical Impedance Tomography-derived Flow Index During Spontaneous Breathing Trial Stratifies the Risk of Reintubation Within 48 h After Extubation
Who cites it
2 citing papers in PubMed.
- EIT-based flow index as a peri-extubation monitoring tool: a reply to "new indexes, old habits".Critical care (London, England) · 2026Article
- New indexes, old habits: a comment on the EIT-derived flow index.Critical care (London, England) · 2026Article
Corrections and comments
- Commented on by
Authors and funding
11 authors.
Funding
Abstract
backgroundSpontaneous breathing trial (SBT) is the standard test of readiness for liberation from invasive mechanical ventilation, but some patients who successfully complete SBT still experience early post-extubation failure. Inspiratory effort during SBT has emerged as an important physiological determinant of weaning tolerance and extubation outcome because it reflects the balance between ventilatory load and respiratory muscle capacity, yet its assessment often requires airway occlusions, dedicated ventilator algorithms, or intermittent measurements. We therefore evaluated whether an electrical impedance tomography (EIT)-derived flow index (EFI) measured during SBT was associated with SBT outcome and with reintubation within 48 h after extubation.
methodsIn this prospective multicenter observational study, mechanically ventilated adults receiving invasive ventilation for at least 48 h underwent a standardized 30-min pressure support SBT with continuous EIT monitoring. EFI was calculated breath by breath from EIT-derived inspiratory flow-time profiles. The primary endpoint was SBT outcome. A prespecified key secondary endpoint was reintubation within 48 h after planned extubation among patients who successfully completed the SBT and underwent extubation according to routine care. EFI discrimination for SBT failure was assessed using receiver operating characteristic analysis. For the post-extubation analysis, 48-h freedom from reintubation was evaluated using Kaplan-Meier analysis and Cox proportional hazards models.
resultsA total of 150 patients were enrolled, of whom 107 successfully completed the SBT and underwent planned extubation. EFI showed excellent discrimination for the primary endpoint of SBT outcome (AUC 0.980) and provided early physiological warning of evolving SBT intolerance. Reintubation within 48 h occurred in 7 of 107 extubated patients. Using the EFI threshold of 1.333 derived from the primary endpoint analysis, patients with EFI < 1.333 had significantly lower 48-h freedom from reintubation than those with EFI ≥ 1.333, and all reintubation events occurred in the EFI < 1.333 group. In univariable Cox analyses, EFI, RSBI, MIP, and P0.1 were each associated with reintubation within 48 h after extubation. Because of severe multicollinearity among these indices and the very small number of events, a combined multivariable model was not pursued.
conclusionsEFI measured during SBT was strongly associated with SBT outcome and showed an exploratory association with reintubation within 48 h after extubation. Beyond identifying SBT intolerance, EFI may help identify patients with residual physiological vulnerability after a successful SBT; however, this secondary finding requires cautious interpretation and external validation.
trial registrationClinicalTrials.gov NCT06876792. Registered on March 10, 2025.