Evidence map›Paper›PMID 42219396›Full record

ArticleScientific reports2026

Deep learning for automatic segmentation of the inferior alveolar nerve using a hybrid CNN-transformer framework.

Ho-Kyung Lim, Seok-Ki Jung, Yongwon Cho, In-Seok Song

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ho-Kyung Lim *Department of Oral and Maxillofacial Surgery, Korea University Guro Hospital, Seoul, 08308, Korea.
Seok-Ki Jung *Department of Orthodontics, Korea University Guro Hospital, Seoul, 08308, Korea.
Yongwon ChoDepartment of Computer Engineering, Soonchunhyang University, Asan-si, Chungcheongnam-do, 31538, Korea. dragon1won@gmail.com.
In-Seok SongDepartment of Oral and Maxillofacial Surgery, Korea University Anam Hospital, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Korea. densis@korea.ac.kr.

Funding

the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea RS-2023-KH134676the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) RS-2026-25477630
6 · The paper itself

Abstract

Accurate identification of the inferior alveolar nerve (IAN) is essential for preventing nerve injury during dental and maxillofacial procedures such as tooth extraction, implant placement, and orthognathic surgery. However, manual annotation of the IAN in cone-beam computed tomography (CBCT) is challenging because of image noise, anatomical variability, and the complex three-dimensional curvature of the nerve pathway. In this study, we propose an improved automatic segmentation framework for IAN identification in CBCTs using a hybrid CNN-attention architecture built upon the nnU-Net framework. The proposed framework introduces a task-specific CNN-attention hybrid architecture with stage-restricted Permuted Adaptive Instance Normalization (Permuted AdaIN) and decoder-stage contextual refinement to improve robustness to appearance variability while preserving anatomical continuity in thin tubular nerve segmentation. Permuted AdaIN is selectively applied to encoder stage 2 to encourage appearance-invariant feature representations while preserving boundary-sensitive anatomical structures. In addition, the decoder attention module refines contextual interactions between encoder and decoder features after skip fusion, improving segmentation consistency of the thin tubular nerve structure. A total of 130 CBCTs from two institutions were used for training and evaluation. The proposed method achieved Dice similarity coefficients of 0.63 ± 0.17 on the internal dataset (KUAH) and 0.62 ± 0.12 on the external dataset (KUGH), showing a modest numerical improvement compared with nnU-Net (0.60 ± 0.18 and 0.59 ± 0.11, respectively). In addition, the proposed method achieved lower boundary errors, with HD95 values of 2.96 ± 1.27 mm and 3.72 ± 7.63 mm, and ASSD values of 1.22 ± 0.49 mm and 1.29 ± 2.10 mm for the internal and external datasets, respectively. Qualitative analysis further demonstrated improved boundary alignment and continuity of the segmented nerve trajectory. These results suggest that the proposed framework may improve segmentation consistency and boundary agreement in automated IAN segmentation on CBCT images, although the magnitude of improvement over nnU-Net should be interpreted cautiously.

Indexed as

Cone-Beam Computed TomographyDeep LearningImage Processing, Computer-AssistedMandibular NerveConvolutional Neural NetworksHumansAutomatic segmentationConvolutional neural networkDeep learningInferior alveolar nerveVision transformer

Identifiers

PMID42219396
PMCPMC13458472

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.