Evidence map›Paper›PMID 42218166›Full record

ArticleScientific reports2026

Effectiveness of Hybrid Surgery Using Polyetheretherketone Rods for Preventing Proximal Junctional Kyphosis and Failure After Adult Spinal Deformity Surgery: Biomechanical Evaluation.

Chao Li, Yao Zhao, Xiangning Meng, Longtao Qi, Beiyu Xu, Chunde Li

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chao Li *Department of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China.
Yao Zhao *Department of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China.
Xiangning Meng *Department of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China.
Longtao QiDepartment of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China.
Beiyu XuDepartment of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China.
Chunde LiDepartment of Orthopedics, Peking University First Hospital, No.8 Xishiku Street, Xicheng District, Beijing, 100034, China. Lichunde@vip.sina.com.

Funding

Capital Health Research and Development of Special Fund 2022-2Z-40713National High Level Hospital Clinical Research Funding 2023YC22National High Level Hospital Clinical Research Funding 2024YC31
6 · The paper itself

Abstract

Proximal junctional kyphosis (PJK) and proximal junctional failure (PJF) are common complications of adult spinal deformity (ASD) surgery. Hybrid fixation techniques have emerged as a potential solution to mitigate this risk. However, the biomechanical benefits of hybrid rod fixation in long-segment spinal surgery have not been fully explored or validated. This study aimed to evaluate the effect of hybrid fixation using both polyetheretherketone (PEEK) rods and titanium rods on the increased incidence of PJK and PJF after long-segment ASD surgery using finite element analysis. A three-dimensional finite element model of the adult spine (T6-S1) was developed to simulate the biomechanical effects of different fixation techniques. An intact spine (model A) and two internal fixation configurations were modeled: model B incorporated titanium rods from T10 to S1 and model C incorporated PEEK rods from T10 to T11 with titanium rods from T11 to S1. Then, the resulting stresses on the intervertebral discs, facet joints, pedicle screws, and fixation rods were analyzed. Under six physiological motion states, intervertebral mobility and maximum von Mises stress on the adjacent segment (T9-T10) intervertebral disc, endplate, and facet joint was greater in models B and C than model A. Furthermore, intervertebral mobility and maximum von Mises stress on the adjacent segment intervertebral disc and facet joint were greater in model B than model C. Under all physiological motion conditions except for extension, the maximum von Mises stress on the adjacent segment endplate was greater in model B than model C. Hybrid fixation using PEEK and titanium rods shows promise for reducing the risk of PJK and PJF after ASD surgery. By decreasing intervertebral mobility and concentration of stress on the adjacent segment, hybrid fixation could improve long-term surgical outcomes and reduce the need for revision surgery.

Indexed as

KetonesKyphosisPolyethylene GlycolsSpinal FusionBenzophenonesBiomechanical PhenomenaFinite Element AnalysisHumansInternal FixatorsPolyether CompoundsPolymersTitaniumBenzophenonesKetonesPolyether CompoundspolyetheretherketonePolyethylene GlycolsPolymersTitaniumComputational modelingFinite element analysisHybrid rod fixationPolyetheretherketoneProximal junctional failureProximal junctional kyphosis

Identifiers

PMID42218166
PMCPMC13490431

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.