Evidence map›Paper›PMID 42213388›Full record

ArticleEJNMMI physics2026

Optimization of brain PET markerless head motion correction in a large human cohort.

Tianyi Zeng, Jiazhen Zhang, Jean-Dominique Gallezot, Kathryn Fontaine, Weize Jiang, Paul Gravel, Tim Mulnix, Mika Naganawa, Zhaohui Yang, Xinyue Zhang and 4 more

Abstract read
In one paragraph

Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Tianyi ZengDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA. tianyi.zeng@yale.edu.ORCID http://orcid.org/0000-0002-5467-062X
Jiazhen ZhangDepartment of Biomedical Engineering, Yale University, New Haven, CT, USA.
Jean-Dominique GallezotDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
Kathryn FontaineDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
Weize JiangUnited Imaging Healthcare, Houston, TX, USA.
Paul GravelDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
Tim MulnixDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
Mika NaganawaDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
Zhaohui YangUnited Imaging Healthcare, Houston, TX, USA.
Xinyue ZhangUnited Imaging Healthcare, Houston, TX, USA.
Su WangUnited Imaging Healthcare, Houston, TX, USA.
Xishan SunUnited Imaging Healthcare, Houston, TX, USA.
Lingzhi HuUnited Imaging Healthcare, Houston, TX, USA.
Richard E CarsonDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.

Funding

NeuroExplorer: Ultra-high Performance Human Brain PET Imager for Highly-resolved In Vivo Imaging of NeurochemistryU01EB029811 · NIBIB · YALE UNIVERSITY · PI CARSON, RICHARD E., LI, HONGDI · 2020 to 2024
$10.0M
NIBIB NIH HHS U01 EB029811NIH HHS U01EB029811
6 · The paper itself

Abstract

purposeUncorrected head motion in brain PET degrades image resolution and biases quantification. Previously, we evaluated the United Imaging Healthcare markerless motion tracking (UMT) system for brain PET (Baseline UMT). This study provides an expanded validation in a large cohort compared to the Vicra with improved methodology (Optimized UMT).

methodsWe developed automatic processing to define the upper face region and added a 2-step Iterative Closest Points registration to reduce non-rigid motion effects. Optimized and Baseline UMT were first compared with simulations using measured motion and intentional facial expressions. In the human study, we evaluated 51 dynamic human studies (Siemens mCT) using 5 radiopharmaceuticals. Vicra data were used as the gold standard, after assessment of motion data quality using motion-corrected centroid-of-distribution. Comparisons between Optimized UMT, no motion correction (NMC), Post-Reconstruction Registration (PRR), and Baseline UMT were performed. Static and dynamic analyses assessed the differences of region-of-interest standardized uptake values (SUV) compared to Vicra. Time activity curve (TAC) analysis was performed to quantify uncorrected motion from the residual standard deviation (SD) around fitted TACs.

resultsIn simulation studies, optimized UMT reduced error by 20% relative to NMC and by 9% relative to Baseline UMT under intentional facial expressions, reflecting the impact of the updated UMT registration. In the human static analysis of SUV, optimized UMT outperformed PRR (+ 1.6%) and NMC (+ 6.5%) on average grey matter difference. Similar results were found in the dynamic analysis. In the TAC analysis, optimized UMT consistently yielded lower residual variability than NMC and PRR across tracers and ROIs, with a narrower range of median %SD values (0.3-1.8%) compared with NMC (1.6-6.5%) and PRR (0.5-1.9%), while demonstrating performance comparable to the reference Vicra-based correction.

conclusionOptimized UMT achieved comparable performance to Vicra and significantly improved quantification over PRR.

Indexed as

Brain PETEvent-by-event correctionHead motionMarkerless motion tracking system

Identifiers

PMID42213388
PMCPMC13433684

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.