Evidence map›Paper›PMID 42212289›Full record

ArticleGynecology and pelvic medicine2026

Robot-assisted sacrocolpopexy using the Hugo-RAS system: initial series with no experience in robotic surgery.

Andrea Albertus-Bofarull, Laura Lorenzo-Soriano, Carlos Domingo-Latorre, Marco Ferrández-Jiménez, Ana I Vilchez-Costas, José D Lorenzo-González, Noelia García-Cárceles, Alejandro Garcia-Segui, Luis Gómez-Pérez

Abstract readCase Reports
In one paragraph

Article in Gynecology and pelvic medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Andrea Albertus-BofarullDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0009-0000-3204-1999
Laura Lorenzo-SorianoDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0000-0002-2156-699X
Carlos Domingo-LatorreDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0000-0001-6577-7329
Marco Ferrández-JiménezDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0000-0002-4736-849X
Ana I Vilchez-CostasDepartment of Urology, University General Hospital of Elche, Elche, Spain.
José D Lorenzo-GonzálezDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0009-0008-4848-3394
Noelia García-CárcelesDepartment of Urology, University General Hospital of Elche, Elche, Spain.
Alejandro Garcia-SeguiDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0000-0001-8114-0542
Luis Gómez-PérezDepartment of Urology, University General Hospital of Elche, Elche, Spain.ORCID https://orcid.org/0000-0003-1396-0484

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pelvic organ prolapse (POP) is a common condition in women that negatively impacts the quality of life, including symptoms and effects on body image and sexuality. Robotic-assisted sacrocolpopexy (RASC) is established as a gold-standard treatment for POP, and most published evidence concerns the da Vinci robotic platform. New robotic systems are expanding the technological landscape; the Hugo-RAS platform is one of the most popular of them. Published experience with Hugo-RAS has focus mainly on prostate cancer and typically comes from centers with previous da Vinci experience. RASC articles with Hugo-RAS are very few. Moreover, the implementation of Hugo-RAS in an inexperienced robotics scenario remains unclear. We present our initial series of Hugo-RAS RASC performed by surgeons without prior robotic surgery experience to evaluate the safety, feasibility, and clinical outcomes. Case Description: Between November 2023 and March 2024, eight consecutive patients with symptomatic POP underwent RASC using Hugo-RAS system. The women included have a POP of ≥3 stage based on the POP-quantification (POP-Q). Perioperative parameters, complications, and functional outcomes were prospectively collected. Procedures were performed by a standardized technique including dissection, mesh placement, fixation to the cervix or vaginal vault and promontory, and peritonealization. A gynecological examination was carried out at discharge and at 45 days using the POP-Q system and the Patient Global Impression of Improvement (PGI-I) scale. The median operative time was 230 [interquartile range (IQR), 190-272] minutes, and the median estimated blood loss was 275 (IQR, 147.5-387.5) cc. The intraoperative complications occurred in one patient (opening of the vagina). The postoperative complications occurred in 2 patients and were Clavien-Dindo grade I-II. Median hospital stay was 3 days. At a median follow-up of 15.5 months, all patients showed objective anatomical improvement without recurrences and reported satisfaction with the surgery. Conclusions: In our preliminary series RASC using Hugo-RAS for the treatment of POP is safe, feasible, and provides satisfactory short-term outcomes even by robotic-naive surgeons. More robust and comparative studies are needed to support these results and determine their definitive role in urogynecologic surgery.

Indexed as

case seriesHugo-RAS systempelvic organ prolapse (POP)robotic-assisted sacrocolpopexy (RASC)Robotic-assisted surgery (RAS)

Identifiers

PMID42212289
PMCPMC13214977

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked