Evidence map›Paper›PMID 42211940›Full record

ArticleFrontiers in molecular biosciences2026

Using native human sera to assess the suitability of external quality assessment materials based on testosterone, progesterone, and 17β-estradiol measurements.

Laura Vierbaum, Patricia Kaiser, Thomas Keller, Stephan Weber, Ingo Schellenberg, Peter B Luppa, Folker Wenzel, Mario Thevis

Abstract read
In one paragraph

Article in Frontiers in molecular biosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Laura VierbaumINSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.
Patricia KaiserINSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.
Thomas KellerACOMED statistik, Leipzig, Germany.
Stephan WeberACOMED statistik, Leipzig, Germany.
Ingo SchellenbergINSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.
Peter B LuppaINSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.
Folker WenzelINSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.
Mario ThevisInstitute of Biochemistry/Center for Preventive Doping Research, German Sport University Cologne, Cologne, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The commonly processed nature of the control materials used in the external quality assessment (EQA) of medical laboratories requires that their suitability is evaluated against native patient samples to ensure valid evaluation of EQA results across several measurement procedures (MPs). The aim of this study was to examine the extent to which EQA analyses of a small number of native human samples in a regular EQA survey can help to assess the suitability of routinely distributed processed EQA materials (EQAMs), demonstrated by testosterone, progesterone, and 17β-estradiol measurements in human sera. Methods: Laboratory results for the native and processed EQAMs were comparatively analyzed using a mixed-effects model. This estimated the sample type-specific mean natural logarithm (ln) bias to the reference measurement value and mean differences in ln bias between the two sample types, each with a 95%-confidence interval. Applying quite strict commutability criteria defined in consideration of clinical guidelines enabled the identification of analyte/reagent manufacturer pairings exhibiting only minor differences in bias between sample types. For pairings showing differences in bias between the two sample types that exceeded the commutability criterion, efforts were made to differentiate between material- and MP-related contributions to the model outcomes - referred to as non-commutability and trueness bias, respectively. Results: Strongly scattered bias of the native EQAMs for some MPs revealed issues with measurement performances, such as inappropriate calibration or specificity. Consistent bias but distinct differences in bias between sample types indicated issues with commutability. The two-stage assessment revealed that the processed EQAMs were suitable for EQA purposes in most pairings. In two exceptions (testosterone/DG and progesterone/BE), the processed materials showed insufficient commutability. The limited number of EQAMs may result in inconclusive commutability assessments for individual analyte/MP pairings, four in this study, but allows for targeted follow-up with additional native EQAMs or comprehensive commutability studies. Conclusion: Compared to conventional commutability studies, these proposed EQA comparability studies that use comparative native EQAMs offer EQA providers a more efficient and resource-conserving approach to assess the suitability and commutability of EQAMs by leveraging existing infrastructures. Nevertheless, even this more pragmatic approach remains resource-intensive and is inherently restricted to specific questions and selected analytes.

Indexed as

17β-estradiolcommutabilitycomparative EQA studiesnative external quality assessment (EQA) materialprogesteronesteroid hormonestestosterone

Identifiers

PMID42211940
PMCPMC13212067

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.