Evidence map›Paper›PMID 42210818›Full record

ArticleMedical engineering & physics2026

Rapid coronary artery stent computational simulation using the simplex deformable model.

Changkye Lee, Shijia Zhao, Wei Wu, Rakshita Ramesh Bhat, Priyansh Patel, Yash Vardhan Trivedi, Parth Munjal, Yoshinobu Murasato, Yiannis S Chatzizisis

Abstract read
In one paragraph

Article in Medical engineering & physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Changkye LeeCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0000-0001-7070-3332
Shijia ZhaoCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0009-0008-2584-2876
Wei WuCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0000-0003-0734-1636
Rakshita Ramesh BhatCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0000-0002-2656-0044
Priyansh PatelCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0000-0002-3002-982X
Yash Vardhan TrivediCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0009-0009-3636-4707
Parth MunjalCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0009-0004-7665-4737
Yoshinobu MurasatoDepartment of Cardiology, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan.ORCID 0000-0003-4825-5347
Yiannis S ChatzizisisCenter for Digital Cardiovascular Innovations, Division of Cardiovascular Medicine, University of Miami, Miami, FL, United States of America.ORCID 0000-0001-8955-0081

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to present and demonstrate the feasibility of a simplex deformable model (SDM) for patient-specific coronary stent simulations in two patient-specific cases. Patient-specific 3D artery anatomies were converted into triangular meshes and then transformed into 2-simplex meshes. For each vertex, three neighboring vertices were used to compute outward and inward normal vectors to model stent expansion and arterial wall resistance. Internal forces representing stent mechanics were computed during expansion, and external forces incorporating non-linear hyperelastic arterial behavior were applied after stent-wall contact. Two patient-specific arteries were simulated using the SDM framework, with the finite element method (FEM) as the reference. Relative to FEM, the SDM achieved 360-670 times faster computational time, and reduced vertex counts by 9.5-12.6 times. Bland-Altman analysis showed small mean biases in mean lumen diameter (-0.029 mm for Artery 1;-0.043 mm for Artery 2), and root mean square error was small (0.063 mm for Artery 1; 0.098 mm for Artery 2), and the mean absolute relative error was also low (1.75% for Artery 1; 2.31% for Artery 2). In conclusion, this proof-of-concept study in two patient-specific 3D coronary anatomies suggests that the proposed SDM-based simulations can achieve overall agreement with FEM, while substantially reducing computational time and mesh size.

Indexed as

Computer SimulationCoronary VesselsMechanical PhenomenaModels, CardiovascularStentsFinite Element AnalysisHumansTime Factorsfinite element analysispatient-specific coronary arteryrapid simulationsimplex deformable model

Identifiers

PMID42210818
PMCPMC13220072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked