Evidence map›Paper›PMID 42207777›Full record

ArticlePloS one2026

Validating hip- and wrist-ActiGraph accelerometer cut-points for physical activity intensities in people living with coronary heart disease.

Nicole Freene, Brad Clark, Maria Bäck, Theo Niyonsenga, Kate Pumpa, Arjun Rangaraj, Tze Hao Wong, Soraya Joseph, Ahmed Khan, Rachel Davey and 1 more

Abstract readValidation Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Nicole FreeneHealth Research Institute, University of Canberra, Canberra, Australia.ORCID https://orcid.org/0000-0002-2047-7012
Brad ClarkResearch Institute for Sport and Exercise, University of Canberra, Canberra, Australia.
Maria BäckDepartment of Health, Medicine and Caring Sciences, Unit of Physiotherapy, Linköping University, Linköping, Sweden.
Theo NiyonsengaHealth Research Institute, University of Canberra, Canberra, Australia.ORCID https://orcid.org/0000-0002-6723-0316
Kate PumpaResearch Institute for Sport and Exercise, University of Canberra, Canberra, Australia.ORCID https://orcid.org/0000-0003-3757-3972
Arjun RangarajCanberra Health Services, Canberra, Australia.
Tze Hao WongCanberra Health Services, Canberra, Australia.
Soraya JosephCanberra Health Services, Canberra, Australia.
Ahmed KhanCanberra Health Services, Canberra, Australia.
Rachel DaveyHealth Research Institute, University of Canberra, Canberra, Australia.
Amanda LönnHealth Research Institute, University of Canberra, Canberra, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

People with coronary heart disease (CHD) are encouraged to meet the public health moderate-to-vigorous aerobic physical activity (MVPA) guidelines for secondary prevention of cardiovascular disease. However, no accelerometer aerobic intensity cut-points are currently available to classify MVPA in this population. This study aimed to establish absolute and relative aerobic physical activity intensity accelerometer cut-points in people with CHD and compare the new with existing cut-points in an international cohort. Eighty-six participants with CHD performed a resting-metabolic-rate (RMR) assessment, activities-of-daily-living (ADLs) and a peak treadmill test with mixed-chamber gas analysis while wearing two ActiGraph GT3X accelerometers (hip and wrist). The average RMR was 2.8 ml.kg-1.min-1, 20% less than the commonly used 1 Metabolic Equivalent of Task (3.5 ml.kg-1.min-1). The study sample was randomly split into a training and independent validation set (2:1) allowing for cross validation. In the training set, there were significant positive correlations between accelerometer counts.min-1 (y-axis, vector-magnitude (VM)) and intensity (relative and absolute) across both accelerometer hip- and wrist-placements for all activities (p < 0.001). Using Generalized Estimating Equation modelling, there was a strong linear relationship between accelerometer counts and absolute intensity for hip-placement (R2 = 0.62-0.71), and weaker relationships for hip relative intensity (R2 = 0.40-0.47) and wrist-placement (R2 = 0.09-0.25). In the validation set, Bland-Altman plots found that the mean differences between predicted and actual absolute and relative intensity measures were negligible for all accelerometer counts.min-1 (y-axis, VM) and placements (hip, wrist), although the dispersion of the differences (95% limits of agreement) were wide. Hip VM counts.min-1 cut-points were found to best identify absolute and relative MVPA. In the international comparison (n = 176), participants completed significantly more MVPA using the new cut-points (p < 0.001). Thus, accelerometer cut-points developed in healthy individuals appear to under-estimate physical activity intensity in this population and cut-points specific to people with CHD should be used. Australian New Zealand Clinical Trials Registry: ACTRN12623000605695.

Indexed as

AccelerometryActigraphyCoronary DiseaseExerciseAgedExercise TestFemaleHipHumansMaleMiddle AgedWrist

Identifiers

PMID42207777
PMCPMC13218503

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.