Evidence map›Paper›PMID 42207595›Full record

ArticleDimensions of critical care nursing : DCCN

Intravenous Smart Pump Alarms in Everyday Hospital Use: A Real-world Descriptive Analysis.

Brenda Abena Nyarko, Cidalia J Vital, Karen K Giuliano

Abstract read
In one paragraph

Article in Dimensions of critical care nursing : DCCN. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Brenda Abena NyarkoElaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA.ORCID 0000-0003-0603-137
Cidalia J VitalElaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA.ORCID 0000-0003-2753-2683
Karen K GiulianoElaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA.ORCID 0000-0003-3047-5421

Funding

University of Massachusetts Amherst Provost Interdisciplinary Research Grant Award and Association for the Advancement of Medical Instrumentation (AAMI) Mary Logan Grant.
6 · The paper itself

Abstract

backgroundFrequent intravenous smart-pump (IVSP) alarms can disrupt workflow, increase alarm fatigue, and threaten patient safety.

objectivesTo describe the frequency, distribution, and care-area variation of IVSP alarms from the Baxter Sigma Spectrum IVSP over a 2-year period at a large academic medical center.

methodsA retrospective study of IVSP alarms was performed for all inpatient areas at a US academic medical center. Alarm events and infusion starts were extracted using the Care Everywhere analytics platform and aggregated by frequency of alarms, number of infusions, alarm type, and care area. Analyses were done using descriptive statistics.

resultsA total of 5,129,505 alarms were linked to 1,102,303 infusion starts (mean = 4.65 alarms per infusion). Four alarm categories accounted for 86.5% of events: downstream occlusion (42.5%), air-in-line (15.5%), infusion complete (14.4%), and upstream occlusion (14.1%). Although they accounted for only 6% of total infusion starts, the NICU, pediatrics, and pediatric intensive care unit (PICU) had the highest alarm rates, averaging 28.6, 9.0, and 7.7 alarms per infusion, respectively. Downstream occlusion rates peaked in Pediatrics (696/100 starts) and PICU (536/100), while upstream occlusions were highest in the NICU (337/100). Air-in-line alarms were greatest in Oncology (103/100).

conclusionDownstream occlusion, air-in-line, infusion-complete, and upstream occlusion alarms dominated the 2 years of alarm data, generating the majority of the 5 million IVSP alarms. Although adult medical-surgical (Med/Surg) and critical care generated the most alarms overall, pediatric and neonatal areas experienced the highest number of alarms per infusion, placing them at the greatest risk for alarm fatigue.

Indexed as

Alert Fatigue, Health PersonnelClinical AlarmsInfusion PumpsInfusions, IntravenousAcademic Medical CentersCritical CareHospitals, PediatricHumansIntensive Care Units, NeonatalIntensive Care Units, PediatricPatient SafetyRetrospective StudiesAlarm fatigueAlarmsInfusion pumps

Identifiers

PMID42207595
PMCPMC13218573

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.