Evidence map›Paper›PMID 42206561›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

TRIM: Simultaneous Thermometry, Ranging, and Imaging via a Monolithic Metalens.

Man Yuan, Yuqing Zhang, Wangzhe Zhou, Zhaojian Zhang, Xiaoyun He, Xinpeng Jiang, Yiyi Li, Xin He, Jiagui Wu, Yuanmu Yang and 1 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Man YuanCollege of Science, National University of Defense Technology, Changsha, China.ORCID https://orcid.org/0009-0000-9045-8995
Yuqing ZhangSchool of Physical Science and Technology, Southwest University, Chongqing, China.
Wangzhe ZhouCollege of Science, National University of Defense Technology, Changsha, China.
Zhaojian ZhangCollege of Science, National University of Defense Technology, Changsha, China.ORCID https://orcid.org/0000-0002-9388-8752
Xiaoyun HeSchool of Physical Science and Technology, Southwest University, Chongqing, China.
Xinpeng JiangCollege of Science, National University of Defense Technology, Changsha, China.ORCID https://orcid.org/0000-0002-1548-3637
Yiyi LiCollege of Science, National University of Defense Technology, Changsha, China.
Xin HeCollege of Science, National University of Defense Technology, Changsha, China.
Jiagui WuSchool of Physical Science and Technology, Southwest University, Chongqing, China.
Yuanmu YangState Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China.ORCID https://orcid.org/0000-0002-5264-0822
Junbo YangCollege of Science, National University of Defense Technology, Changsha, China.ORCID https://orcid.org/0000-0003-1093-5611

Funding

Chongqing Natural Science Foundation CSTB2024NSCQ-LZX0033Chongqing Natural Science Foundation CSTB2024NSCQ-MSX0581National Key Research and Development Program of China 2022YFF0706005National Natural Science Foundation of China 12272407National Natural Science Foundation of China 62275269National Natural Science Foundation of China 62275271National Natural Science Foundation of China 62305387National Natural Science Foundation of China 62405037
6 · The paper itself

Abstract

While metasurfaces offer a pathway beyond the discrete architectures of conventional LWIR systems, physically fusing high-precision thermometry and passive ranging onto a single metalens remains a formidable challenge. Here, we demonstrate a monolithic, dual-focus metalens capable of simultaneous multidimensional sensing. By multiplexing two distinct focal lengths into a single metasurface, the system enables the parallel acquisition of spectral and spatial information. For thermal sensing, we implement a dual-band (9.6 and 10.6 µm) ratiometric method that effectively mitigates target emissivity uncertainty under the gray-body assumption. This approach yields a mean absolute temperature error of 13.58°C (∼3% relative error) and exhibits exceptional linearity (R

Indexed as

long‐wave infrared (LWIR)metalensmonolithic integrationmultidimensional sensingpassive rangingratiometric thermometry

Identifiers

PMID42206561
PMCPMC13336119

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.