ArticleJMIR cardio2026
Extracting Cardiorespiratory Symptoms From Clinical Notes Using Open-Weight Large Language Models: Method Development and Validation Study.
Article in JMIR cardio, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Accurate identification of clinical symptoms and signs (S&S) is essential for the early detection of high-burden cardiorespiratory conditions, including lung cancer, chronic obstructive pulmonary disease, and heart failure. Although symptom data play a central role in diagnostic reasoning and predictive modeling, most S&S information remains embedded in unstructured electronic health record notes, limiting their use in automated phenotyping, surveillance, and clinical decision support. Traditional natural language processing systems struggle with domain variability and contextual nuance in clinical text. Recent advances in large language models (LLMs) offer a promising alternative, yet challenges remain in hallucinations, overinference, and safe deployment. This study evaluated whether locally deployed open-source models could reliably extract cardiorespiratory S&S and map them to ICD-10-CM (International Classification of Diseases, Tenth Revision, Clinical Modification) codes using optimized prompting strategies. Objective: This study aims to assess the accuracy of open-source LLMs in extracting explicitly stated cardiorespiratory S&S from clinical notes and mapping them to ICD-10-CM codes (R00-R09) and to compare performance across 4 prompt-engineering strategies, including a multimodule LLM framework. Methods: A total of 593 clinical notes from the MTSamples database were manually reviewed, with 93 notes used for prompt development and comparison using Llama 3.3-70B, and 500 notes used as testing data for the final best prompt setting using both Llama 3.3-70B and gpt-oss-120B. Four prompting conditions were evaluated: (1) instruction-only, (2) ICD-10-CM definition-based prompts, (3) assumption-free prompts, and (4) a multimodule LLM framework with postprocessing. Performance was measured using precision, recall, and F1-score for both S&S extraction and ICD-10-CM code generation. Results: Across all prompt strategies, model performance improved as more structure and constraints were added. Instruction-only prompting demonstrated high recall but poor precision. Incorporating ICD-10-CM definitions improved coding accuracy, and assumption-free prompting further balanced precision and recall. The multimodule approach with postprocessing achieved the highest performance during prompt development. On the independent test corpus, entity-level microaveraged evaluation showed that gpt-oss-120B outperformed Llama 3.3-70B in both tasks. For S&S extraction, Llama 3.3-70B achieved a precision of 0.63, a recall of 0.86, and an F1-score of 0.73, whereas gpt-oss-120B achieved a precision of 0.89, a recall of 0.87, and an F1-score of 0.88. For ICD-10-CM code mapping, Llama 3.3-70B achieved a precision of 0.59, a recall of 0.83, and an F1-score of 0.69, whereas gpt-oss-120B achieved a precision of 0.90, a recall of 0.84, and an F1-score of 0.87. Conclusions: Locally deployed LLMs, when paired with optimized prompting and multimodule orchestration, can accurately extract cardiorespiratory S&S and generate ICD-10-CM codes from unstructured clinical notes. This approach increases the level of data safety by enabling on-premises processing without external data transmission and demonstrates strong potential for scalable, domain-adaptive symptom extraction pipelines in biomedical informatics. Future work should expand datasets and evaluate generalizability across clinical domains.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.