ArticleScientific reports2026
Double deep reinforcement learning twin-delayed agents for performance improvement of a grid-connected wave energy conversion system.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study introduces a novel approach using two deep learning agents, trained with the twin-delayed deep deterministic policy gradient (TD3) algorithm, to replace the PI controllers used for the control of grid-connected Archimedes Wave Swing (AWS) wave energy conversion systems. The generator converter's controller has two mandatory objectives: minimizing losses in the stator and maximizing energy extraction from incident sea waves. These goals are achieved by controlling the generator's dq currents using a TD3 agent on the rectifier side. In addition, the grid-side inverter's controller is responsible for regulating both the DC link and the point-of-common-coupling voltages. In the new configuration, two approaches are proposed in this work: either a single deep learning agent replaces the four proportional-integral (PI) controllers on the inverter side, or a hybrid approach combining two PI controllers with a TD3 agent. To verify the reliability of the TD3 agents, the system is analyzed in both steady and transient states under fault conditions. Furthermore, the TD3 agents' performance is benchmarked against the classical PI controller configuration in MATLAB Simulink. The results demonstrate better dynamic and steady-state responses from the hybrid-TD3 agent on the grid side than from the full PI classical configuration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.