Evidence map›Paper›PMID 42203819›Full record

ArticleScientific reports2026

A low-complexity subtraction-based weighting coefficient for synthetic aperture ultrasound imaging.

Roya Paridar, Babak Mohammadzadeh Asl

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Roya ParidarDepartment of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran.
Babak Mohammadzadeh AslDepartment of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran. babakmasl@modares.ac.ir.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A major challenge in medical ultrasound beamforming is developing algorithms capable of producing high-resolution images. The minimum variance (MV) algorithm achieves higher resolution than the delay-and-sum (DAS) approach but suffers from high computational cost, limiting its practical use. Recently, the null subtraction imaging (NSI) algorithm has been proposed, offering high resolution with significantly lower complexity than MV. However, its main drawback is the loss of background speckle information. In this paper, a novel method is introduced to simultaneously achieve high resolution and preserve background speckle. The proposed technique reconstructs a high-resolution image while maintaining speckle characteristics comparable to those of DAS. Appropriate weights are determined based on a subtraction process between beamformed images corresponding to two transmit sub-arrays. Moreover, the computational burden of the proposed method is low, making it suitable for real-time applications. Simulated and experimental evaluations demonstrate that the proposed technique outperforms the MV and NSI algorithms in terms of resolution enhancement. Furthermore, among existing methods, it uniquely achieves simultaneous improvement in image resolution, contrast, and background speckle preservation.

Indexed as

High resolutionLow complexitySpeckle preservationSynthetic transmit apertureUltrasound

Identifiers

PMID42203819
PMCPMC13447974

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.