Evidence map›Paper›PMID 42202019›Full record

ArticleScience advances2026

An integrated wireless deep-UV sensing system for intelligent early fire detection.

Taehyun Park, Junhwa Oh, Junhyung Cho, Seungme Kang, Nicola Gasparini, Wooseok Song, Jaehyun Hur, Garam Bae, Seyong Oh, Hocheon Yoo

Abstract read
In one paragraph

Article in Science advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Taehyun ParkDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0001-9119-9518
Junhwa OhDivision of Electrical Engineering, Hanyang University ERICA, 55 Hanyangdaehak-ro, Ansan 15588, Republic of Korea.ORCID 0009-0000-9277-8159
Junhyung ChoDepartment of Artificial Intelligence Semiconductor Engineering, Hanyang University, 222 Wangsimni-ro, Seoul 04763, Republic of Korea.ORCID 0009-0007-0043-3294
Seungme KangDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
Nicola GaspariniDepartment of Chemistry and Centre for Processable Electronics, Imperial College London, London SW7 2AZ, UK.ORCID 0000-0002-3226-8234
Wooseok SongThin Film Materials Research Center, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea.ORCID 0000-0002-0487-2055
Jaehyun HurSchool of Chemical, Biological, and Battery Engineering, Gachon University, Gyenggi 13120, Republic of Korea.ORCID 0000-0003-1604-6655
Garam BaeDepartment of Physics, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea.ORCID 0000-0001-7795-7554
Seyong OhDivision of Electrical Engineering, Hanyang University ERICA, 55 Hanyangdaehak-ro, Ansan 15588, Republic of Korea.ORCID 0000-0002-3989-1117
Hocheon YooDepartment of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.ORCID 0000-0003-0772-3327

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Uncontrolled fires, from wildlands to industrial facilities, have become a pressing global threat, causing widespread ecological damage, loss of life, and economic disruption. The fundamental challenge is the lack of rapid and reliable detection at the ignition stage. Once flames spread, suppression becomes increasingly difficult and damage escalates. Conventional methods such as smoke detectors and thermal imaging fall short for wildfire and large-scale fire scenarios. Effective systems require accurate detection without false activation, stable performance under varied and harsh environments, and low power or zero-bias photodetection for continuous use in remote locations. Here, we report a wireless and flexible deep-ultraviolet (DUV) sensing platform that addresses these requirements in a single integrated unit. The platform combines a zinc tin oxide nanocomposite photodetector, flexible circuit integration, portable power, and Bluetooth communication. The sensor shows a selective solar-blind DUV response, stable operation under mechanical stress and extended cycling (92.5% retention after 100 bending cycles and 96.7% after 180 days), and energy-efficient performance compatible with autonomous deployment. Data-driven analysis of response curves allows for machine learning models that classify flame types and estimate distance, extending the system beyond binary fire detection by providing additional information on flame type and relative distance. This integrated approach provides a practical route to reliable fire monitoring, relevant to early-stage fire monitoring concepts for wildfire and industrial safety applications.

Identifiers

PMID42202019
PMCPMC13215196

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.