Evidence map›Paper›PMID 42201794›Full record

ArticleJournal of the American Academy of Orthopaedic Surgeons. Global research & reviews2026

Findings From 333 Retrieved MoM Total Hip Arthroplasty Components of a Single Design Reveal Modular Interface Corrosion as Most Common Feature.

Sang-Hyun Park, Taber M Ball, Melissa Rupert, Sophia N Sangiorgio, Edward Ebramzadeh

Abstract read
In one paragraph

Article in Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sang-Hyun ParkFrom the J. Vernon Luck, Sr., MD Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance with UCLA (Dr. Park, Ms. Ball, Ms. Rupert, Dr. Sangiorgio, and Dr. Ebramzadeh); the Department of Orthopaedic Surgery (Dr. Park, Dr. Sangiorgio, and Dr. Ebramzadeh); the Department of Life Sciences (Ms. Ball); and the Department of Bioengineering, University of California, Los Angeles, CA (Ms. Rupert and Dr. Sangiorgio).
Taber M Ball
Melissa Rupert
Sophia N Sangiorgio
Edward EbramzadehORCID 0000-0001-5282-8465

Funding

Luskin Orthopaedic Institute for Children Foundation, DePuy Orthopaedics
6 · The paper itself

Abstract

backgroundHigh revision rates and adverse reactions to metal debris led to the discontinuation of most metal-on-metal (MoM) hip systems nearly a decade ago, including the DePuy Pinnacle. This study presents the largest retrieval analysis of this design, investigating relationships among femoral head and acetabular liner taper corrosion, bearing surface wear, and implant design features.

methodsAll 333 retrieved Pinnacle MoM implants from North America, Australia, and Japan, collected between 2013 and 2023, were inspected. Taper corrosion was assessed using the Visual Grading System. Bearing surface wear and diametral clearance were quantified using coordinate measuring techniques. Correlations between taper damage, bearing wear, clearance, and time in vivo were evaluated using nonparametric statistical tests.

resultsComponents were in vivo for a median of 5 years (1 day to 14 years). Median combined volumetric wear was 6.9 mm3 (0.5 to 568.9 mm3), and the median wear rate was 1.8 mm3/yr (0.1 to 191.0 mm3/yr). Moderate or severe corrosion (Visual Grading System ≥ 4) was observed in 60% of head tapers, with severity correlated with time in vivo (P < 0.01). Smaller taper diameters, particularly mini tapers, exhibited higher corrosion scores (P < 0.01). Flexural rigidity ranged from 30.5 to 389.0 N·m2, and more flexible tapers correlated with higher corrosion scores (P < 0.01). Combined volumetric wear correlated with time in vivo (P < 0.01), whereas lower clearance was associated with reduced wear rates (P < 0.01). High-clearance components (>100 µm) showed markedly greater wear and liner taper corrosion (P < 0.01).

conclusionsThe results indicate that higher head/liner clearance was associated with higher volumetric wear and higher liner taper corrosion, but not with head taper corrosion. Although causality is difficult to establish, low femoral stem taper flexural rigidity and high clearance were likely the most important factors resulting in the failures in this cohort.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisMetal-on-Metal Joint ProsthesesProsthesis DesignProsthesis FailureAgedCorrosionFemaleHumansMaleMiddle AgedReoperation

Identifiers

PMID42201794
PMCPMC13209496

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.