Evidence map›Paper›PMID 42199827›Full record

ArticlePhysics and imaging in radiation oncology2026

First evaluation of in-patient dose calculation accuracy on a C-arm Linear Accelerator with advanced Cone-Beam computed tomography (CBCT) imaging.

Kenneth W Gregg, Theodore Arsenault, Sagar Regmi, Kyle O'Carroll, Beatriz Guevara, Meiying Xing, Runyon Woods, Atefeh Rezaei, Rojano Kashani, Lauren Henke and 1 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kenneth W GreggDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Theodore ArsenaultDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Sagar RegmiDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Kyle O'CarrollDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Beatriz GuevaraDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Meiying XingDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Runyon WoodsDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Atefeh RezaeiDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Rojano KashaniDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Lauren HenkeDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.
Alex PriceDepartment of Radiation Oncology, University Hospitals Seidman Cancer Center, Cleveland, OH, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: Innovations in on-board Cone-Beam Computed Tomography (CBCT) show promise for accurate dose calculation due to higher CT number precision compared to prior C-arm CBCT systems. We prospectively investigated dose calculation accuracy in patients imaged using a C-arm linac equipped with an advanced CBCT imaging solution utilizing iterative reconstruction algorithms. Materials and Methods: For image acquisition, 37 patients underwent both a CT-simulation (CT-sim) and high-quality C-arm CBCT in their treatment position. A total of 39 plans (2 patients multi-site) across four body sites (10 Head/Neck, 9 Thorax, 10 Abdomen, 10 Pelvis) were developed on the clinical CT-sim image and recalculated on the CBCT. Dose distributions were compared using 3D gamma analysis passing rates (GPR) using 1%/1mm local criteria and 10% or 50% low-dose thresholding (10%TH, 50%TH). Percent difference in target dose-volume histogram (DVH) metrics D99%, D Results: The CBCT to CT-sim dose calculation comparisons overall GPR with 10%TH averaged 96.2 ± 3.6% and 50%TH GPR average was 95.0 ± 6.9%. Overall, 36 plans at 10%TH and 32 plans at 50%TH achieved > 90% GPR. Percent difference in target DVH metrics averaged 0.15 ± 1.24%, 0.52 ± 1.01%, 0.86 ± 1.29%, -0.92 ± 4.84%, and -0.31 ± 2.42% for D99%, D Conclusion: C-arm CBCT dose calculation was comparable to standard-of-care CT-sim in most patients, demonstrating the ability to be used for clinical evaluation and decisions. Direct dose calculations in settings of minimal anatomical motion were most robust

Indexed as

Direct CBCT Dose CalculationHyperSightTrueBeam

Identifiers

PMID42199827
PMCPMC13200127

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.