Evidence map›Paper›PMID 42199583›Full record

ArticleCureus2026

Multiple Rod Construct for Occipito-Cervical Fusion: Overcoming Challenges With Enabling Technologies.

Bharat R Dave, Arjit Vashishtha, Ajay Krishnan, Shivanand C Mayi, Ravi Ranjan Rai, Mirant B Dave, Mukesh Patel, Mikeson Panthackel, Amritesh Singh, Saurabh S Kulkarni and 1 more

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Bharat R DaveSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Arjit VashishthaSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Ajay KrishnanSpine Surgery, Bhavnagar Institute of Medical Sciences (BIMS), Bhavnagar, IND.
Shivanand C MayiSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Ravi Ranjan RaiSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Mirant B DaveSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Mukesh PatelNeurosurgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Mikeson PanthackelSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Amritesh SinghSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Saurabh S KulkarniSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Yogenkumar AdodariyaSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Occipito-cervical fusion is a well-established procedure for numerous cranio-vertebral junction (CVJ) anomalies. Owing to the complex biomechanics at play in this region, rigid internal fixation with pedicle screws and rods is needed to provide stability for fusion and good clinical outcomes. However, the rates of implant failure are still worrisome, especially in individuals with compromised anatomy and physiology. We describe a method for using multiple rod constructs for instrumentation across the CVJ, making the construct biomechanically stable, achieving high fusion rates, and preventing complications such as implant failure. Methodology This is a retrospective observational study with 10 patients who underwent occipito-cervical fusion with navigation-guided cervical pedicle screw fixation and multiple rod constructs, with a minimum follow-up of 12 months. Clinical parameters, including Visual Analog Scale (VAS), Neck Disability Index (NDI), Nurick grade, and modified Japanese Orthopaedics Association (mJOA) score, were evaluated pre-operatively and at follow-up. Similarly, radiological parameters such as occiput to axis (O-C2) lordosis, subaxial cervical spine (C2-C7) lordosis, and clivus-canal angle (CCA) were evaluated. Assessment of fusion was done by CT scan at 12 months post-operatively. Results All patients improved in terms of clinical and radiological outcomes post-operatively. Early mobilization on post-op day 1 with a soft cervical collar was possible in all the patients. No evidence of implant failure was seen in any of the cases. On follow-up CT scans, bony trabeculae formation was seen in all the patients. Conclusion Multiple rod construct for stabilizing the CVJ for occipito-cervical fusion is associated with early mobilization and clinical as well as radiological improvement due to the biomechanically stable construct provided by multiple anchorage in the cervical spine and occiput. This leads to high fusion rates, especially in patients with compromised anatomy and physiology.

Indexed as

craniovertebral junctionenabling technologiesintra-operative ct and navigation guidancemultiple-rod constructoccipito-cervical fusion surgery