ArticleNeurointervention2026
Multiple Overlapping Low-Profile Visualized Intraluminal Support Stents for Large Extracranial Carotid Artery Aneurysms: A Case Series.
Article in Neurointervention, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Extracranial carotid artery aneurysms (ECAAs) are rare, and the optimal therapeutic modality for these lesions remains controversial. Surgical resection and covered stents may be limited to selected cases. While the concept of using flow diversion is appealing for large aneurysms, the application of flow diverters in extracranial carotid lesions may face restrictions due to off-label use, reimbursement challenges, and factors related to the devices themselves. We report our experience with multiple overlapping Low-profile Visualized Intraluminal Support (LVIS) stents as a reconstructive option for selected ECAAs. Five patients with large ECAAs were treated with multiple overlapping LVIS stents. The primary goal was parent-artery reconstruction and reduction of intra-aneurysmal flow reduction by increasing local metal coverage across the neck of the aneurysm. Double overlapping LVIS stents were used in 3 cases, whereas triple or more extensive overlapping constructs were used in 2 cases. During a mean radiologic follow-up of 24 months, complete occlusion in 2 cases, partial occlusion in 3 cases, and adjunctive procedures in 3 cases were required, and no major thromboembolic or hemorrhagic complications were documented. Adjunctive or staged treatment was required in 3 cases, including balloon angioplasty, additional LVIS stenting, flow-diverter placement, stent-graft placement, or coil embolization. Multiple overlapping LVIS stenting is a feasible and relatively safe reconstructive option for selected large or clinically significant ECAAs, particularly when primary flow-diverter treatment is constrained by off-label indication or reimbursement issues. However, they have limited standalone efficacy, particularly in large or complex aneurysms, often requiring adjunctive or staged treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.