Evidence map›Paper›PMID 42198069›Full record

ArticleSensors (Basel, Switzerland)2026

SparseTrack: A Physics-Informed Transformer Framework for Real-Time Human Motion Reconstruction from Sparse IMUs.

Adithya Balasubramanyam, Suchir Murali Velpanur, Sushma Edhala Jeevarathnam, Tejasree Chekuri Jayachandra, Prasad Honnavalli, Gowri Srinivasa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Adithya BalasubramanyamDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0000-0002-7641-0511
Suchir Murali VelpanurDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0009-0009-5246-7001
Sushma Edhala JeevarathnamDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0009-0009-0671-9597
Tejasree Chekuri JayachandraDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0009-0007-8587-7176
Prasad HonnavalliDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0000-0001-7493-6221
Gowri SrinivasaDepartment of Computer Science and Engineering, PES University, Bengaluru 560085, India.ORCID 0000-0002-3568-6749

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable inertial measurement units are widely used for human motion analysis due to their portability; however, most IMU-based motion capture systems rely on dense sensor configurations that increase cost, complexity, and usability challenges in real-world applications. To address this limitation, this paper presents a sparse inertial human motion reconstruction framework that uses only five wearable sensors while maintaining real-time performance and biomechanical plausibility. The proposed framework integrates Movella Xsens DOT IMUs with a learning-based inverse kinematics pipeline and a real-time biomechanical digital twin for motion reconstruction and visualization. The evaluation was conducted in two phases: first, a real-time motion streaming system was established to validate sensor alignment, coordinate frame consistency, and end-to-end latency; second, a sparse inference framework was trained using the Virginia Tech Natural Motion Dataset combined with a custom dataset containing hard negative samples. Experimental results show that the system can accurately reconstruct full-body human motion, excluding head movement, with a local Mean Per-Joint Position Error of 5.96 cm using only five sensors. Comparative ablation studies demonstrate that Transformer-based temporal modeling achieves better geometric accuracy and temporal smoothness than recurrent and convolutional baselines, while physics-informed regularization and hard negative mining significantly improve biomechanical consistency and reduce motion jitter. Real-time experiments further demonstrate that the framework operates within interactive latency limits, highlighting its potential for biomechanical digital twin applications.

Indexed as

Motion CaptureMovementAlgorithmsBiomechanical PhenomenaHumansWearable Electronic Devicesbiomechanical constraintsdigital twinshuman motion reconstructionreal-time motion capturesparse inertial sensingtransformers

Identifiers

PMID42198069
PMCPMC13210949

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.