ArticleSensors (Basel, Switzerland)2026
A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Contactless vital signs monitoring is becoming increasingly relevant in scenarios where conventional sensors are impractical or not recommended. In this manuscript, a radar-based contactless system for the joint reconstruction of phonocardiogram (PCG) waveforms and cardiac state segmentation is illustrated. The proposed method exploits a self-attention one-dimensional (1D) U-Net fed by a pre-processed radar-derived input to estimate a PCG-like waveform, its envelope, and the four main cardiac phases: S1, systole, S2, and diastole. The accuracy of our method has been assessed on a public synchronized radar-PCG dataset acquired by means of a 24 GHz Doppler radar and a digital stethoscope. On the test subset, the proposed model achieved a 13.4885 dB reduction in log-spectral distance relative to the radar input signal, indicating a marked improvement in waveform fidelity. Segmentation performance also improved, with Micro-F1 increasing from 74.41% to 84.17% and Macro-F1 from 68.40% to 80.43% on average. Experimental results demonstrated the viability of real-time low-power embedded hardware deployment for contactless auscultation and continuous cardiac monitoring applications. The findings confirm that respiratory interference and low-amplitude signals complicate S2 detection, especially when exacerbated by subject motion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.