Evidence map›Paper›PMID 42197945›Full record

ArticleSensors (Basel, Switzerland)2026

Protection-Oriented Non-Intrusive Arc Fault Detection in Photovoltaic DC Systems via Rule-AI Fusion.

Lu HongMing, Ko JaeHa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Lu HongMingDepartment of Electrical Engineering, Honam University, 417 Eodeung-daero, Gwangsan-gu, Gwangju 62399, Republic of Korea.ORCID 0009-0004-0569-7385
Ko JaeHaDepartment of Electrical Engineering, Honam University, 417 Eodeung-daero, Gwangsan-gu, Gwangju 62399, Republic of Korea.ORCID 0000-0003-0062-0253

Funding

Institute of Information & Communications Technology Planning & Evaluation IITP-2026-RS-2022-00156287
6 · The paper itself

Abstract

Series arc faults on the DC side of photovoltaic (PV) systems are a critical hazard that can trigger system fires. Conventional contact-based detection methods suffer from cumbersome installation and high retrofit cost, whereas existing non-contact approaches mostly rely on megahertz-level high-frequency sampling and therefore require expensive radio-frequency instrumentation or high-performance computing platforms. As a result, it remains difficult to simultaneously achieve strong interference immunity and real-time performance on low-cost embedded devices with limited resources. To address this engineering paradox between high-frequency sampling and constrained computational capability, this paper proposes a fully embedded, non-contact arc fault detection system based on a 12-80 kHz low-frequency sub-band selection strategy. By exploiting the physical characteristic of broadband energy elevation induced by arc faults, the proposed strategy avoids dependence on high-bandwidth hardware. Guided by this strategy, a Moebius-topology coaxial shielded loop antenna is employed as the near-field sensor, while an ultra-simplified passive analog front end is constructed directly by using the on-chip programmable gain amplifier and analog-to-digital converter of the microcontroller unit, enabling efficient signal acquisition and fast Fourier transform processing within the target sub-band. To cope with complex background noise in the low-frequency range, an environment-adaptive baseline mechanism based on exponential moving average and exponential absolute deviation is developed for dynamic decoupling. In addition, a lightweight INT8-quantized multilayer perceptron is introduced as a nonlinear auxiliary module, thereby forming a robust hybrid decision architecture with complementary rule-based and artificial intelligence components. Experimental results show that, under the tested household, laboratory, and PV-site conditions, the proposed system achieved an overall detection rate of 97%, while the remaining 3% mainly corresponded to failed ignition or non-sustained arc attempts rather than persistent false triggering during normal monitoring.

Indexed as

DC arc fault detectionembedded systemslow-frequency sub-band selectionnear-field magnetic sensingphotovoltaic (PV) systemsrule-AI fusionshielded loop antenna

Identifiers

PMID42197945
PMCPMC13210839

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.