Evidence map›Paper›PMID 42197921›Full record

ArticleSensors (Basel, Switzerland)2026

Multi-Stage State Assessment of Breakers Based on TCWGAN-GP and XGBoost Under Insufficient Samples.

Lixia Sun, Ling Wang, Jiahao Wang, Zijia Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lixia SunSchool of Electrical and Power Engineering, Hohai University, Nanjing 210098, China.
Ling WangSchool of Electrical and Power Engineering, Hohai University, Nanjing 210098, China.
Jiahao WangSchool of Electrical and Power Engineering, Hohai University, Nanjing 210098, China.
Zijia LiuSchool of Electrical and Power Engineering, Hohai University, Nanjing 210098, China.

Funding

National Natural Science Foundation of China 52077058
6 · The paper itself

Abstract

The increasing randomness and volatility of renewable energy resources have raised higher demands for circuit breakers. Utilizing monitoring data enables more accurate condition assessment; however, the imbalance between fault and normal samples hampers the performance of machine-learning-based assessment. To address the overfitting and limited diversity of traditional oversampling methods, this paper proposes a Transformer-conditioned CWGAN-GP (TCWGAN-GP) model to generate multi-class fault samples for data augmentation. The generator of the proposed model takes random noise and class labels as input to capture the distribution characteristics of real fault samples. By combining a transformer-based generator to model inter-feature dependencies among 14 monitoring indicators and a WGAN-GP training objective with gradient penalty, the proposed approach improves training stability and synthetic sample quality. Moreover, a three-stage state assessment method based on XGBoost is developed to sequentially assess health status, fault category, and fault severity. Results demonstrate that the proposed method in the paper outperforms conventional data augmentation methods and single-stage classifiers in terms of accuracy, recall, F1-score, and online prediction efficiency. Specifically, the proposed three-stage model achieves an overall assessment accuracy of 93.10%, outperforming the single-stage XGBoost framework. In terms of online efficiency, the initial anomaly detection stage requires only 0.0041 s per sample, which is a substantial reduction compared to the 0.0241 s required by the single-stage model. Furthermore, compared to traditional Random Oversampling (ROS) and SMOTE, the TCWGAN-GP augmentation yields superior evaluation performance on fully balanced datasets, achieving a recall rate of 91.26% and an F1-score of 92.61%. Overall, the proposed TCWGAN-GP and three-stage XGBoost method contributes to addressing data imbalance challenges and improving the accuracy of circuit breaker state assessment.

Indexed as

circuit breakercondition assessmentdata imbalanceTCWGAN-GPthree-stage assessmentXGBoost

Identifiers

PMID42197921
PMCPMC13211029

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.