Evidence map›Paper›PMID 42197902›Full record

ArticleSensors (Basel, Switzerland)2026

High-Precision and Efficient Calibration of Robot Polishing Systems Using an Adaptive Residual EKF Optimized by MIPO.

Lei Wang, Yuqi Yao, Shouxin Ruan, Hainan Li, Xinming Zhang, Yiwen Zhang, Zihao Zang, Zhenglei Yu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lei WangSchool of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Yuqi YaoSchool of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.ORCID 0009-0004-3514-2129
Shouxin RuanChina FAW Group Corporation Limited, Changchun 130000, China.
Hainan LiFAW Tooling Die Manufacturing Co., Ltd., Changchun 130013, China.
Xinming ZhangSchool of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.ORCID 0000-0002-6713-1430
Yiwen ZhangSchool of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.ORCID 0009-0005-7387-917X
Zihao ZangSchool of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Zhenglei YuCollege of Biological and Agricultural Engineering, Jilin University, Changchun 130012, China.

Funding

Jilin Province Science and Technology Department 20240301008ZD
6 · The paper itself

Abstract

This paper proposes an adaptive residual extended Kalman filter method optimized by a multi-strategy improved parrot optimization algorithm (MIPO-ARKEKF) to improve the kinematic parameter calibration accuracy and efficiency of robotic polishing systems. To address the limitations of the standard extended Kalman filter (EKF), such as truncation-error accumulation during repeated linearization and sensitivity to manually selected noise parameters, an integrated improvement framework is developed. Specifically, a gradient stabilizer based on state-estimation increments is introduced to alleviate estimation degradation caused by accumulated truncation errors, while the proposed MIPO algorithm is employed to adaptively optimize the process and measurement noise covariance matrices, thereby improving the robustness of parameter identification under practical measurement uncertainty. The calibration process is established on the basis of high-precision external measurement data obtained from the robotic polishing system. In benchmark-function tests, MIPO demonstrates superior convergence performance. In physical experiments based on a KUKA KR210 R2700 robot, the proposed MIPO-ARKEKF method reduces the root mean square positioning error from 0.8927 mm to 0.4858 mm, corresponding to a 45.58% improvement in accuracy. Compared with representative hybrid calibration methods, the proposed method achieves comparable compensation accuracy while reducing computation time by 34.88% to 65.08%. Practical polishing experiments on ultra-low-expansion glass lenses further verify that the proposed method effectively improves end-effector trajectory tracking accuracy and polishing quality, providing an efficient solution for high-precision robotic polishing.

Indexed as

extended Kalman filterparrot optimization algorithmrobot calibrationrobot polishing systemsensor measurement

Identifiers

PMID42197902
PMCPMC13210938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.