Evidence map›Paper›PMID 42197901›Full record

ArticleSensors (Basel, Switzerland)2026

Evolution Mechanism and High-Precision Quantitative Identification of MFL Signals from Defects Under Supersaturated Magnetization Conditions.

Huiqi Zou, Jiuxin Wang, Qi Dong, Dingze Lu, Yurong Du, Yaoheng Su

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Huiqi ZouSchool of Science, Xi'an Polytechnic University, Xi'an 710048, China.
Jiuxin WangShaanxi Special Equipment Inspection and Testing Institute, Xi'an 710048, China.
Qi DongSchool of Science, Xi'an Polytechnic University, Xi'an 710048, China.
Dingze LuSchool of Science, Xi'an Polytechnic University, Xi'an 710048, China.ORCID 0000-0001-8915-8071
Yurong DuShaanxi Special Equipment Inspection and Testing Institute, Xi'an 710048, China.
Yaoheng SuSchool of Science, Xi'an Polytechnic University, Xi'an 710048, China.

Funding

Key Research and Development Program Project of Shaanxi Province Administration for Market Regulation 2024ZDKY17
6 · The paper itself

Abstract

Magnetic flux leakage (MFL) testing is a critical non-destructive testing (NDT) method for ensuring the safety of ferromagnetic storage and transportation equipment. However, existing research has predominantly focused on weak or saturated magnetization states, leaving the characteristic laws and physical mechanisms of defect signals under supersaturated magnetization conditions unclear. To address this gap, this paper systematically investigates the MFL signal evolution mechanism and develops a high-precision quantitative identification method for defects under supersaturated magnetization conditions through finite element simulation, theoretical modeling, and experimental validation. First, a three-dimensional (3D) finite element model for MFL testing is established using COMSOL Multiphysics. The regulatory effects of key parameters-sensor lift-off value, defect burial depth, length, and depth-on the peak values and distribution characteristics of axial and radial MFL signals are revealed, a signal peak characterization model for each parameter and their adjusted R2 is obtained via fitting, and the detection capability of the detector for defects with different shapes is simultaneously verified. Furthermore, actual detection is conducted on three crack defects of different sizes, and the analysis results indicate that the characterization models of each parameter obtained from the simulation exhibit high accuracy. The results show that MFL signal intensity under supersaturated magnetization conditions is significantly enhanced compared to that under saturated magnetization conditions. Furthermore, to improve defect length measurement accuracy, a signal correction method based on the midpoint of extreme values of the second derivative of axial signals is proposed. By compensating for peak offsets caused by factors like magnetic field diffusion, this method reduces the maximum defect length identification error from 14.25% (pre-correction) to below 0.3%. This study elucidates the coupling influence mechanism of multi-physical parameters on MFL signals under supersaturated magnetization conditions. The proposed high-precision signal correction method provides a novel theoretical basis and technical approach for the accurate quantification and inversion of defects in complex operating conditions.

Indexed as

finite element simulationmagnetic flux leakage testingsignal characterization modelsignal correction methodsupersaturated magnetization

Identifiers

PMID42197901
PMCPMC13210713

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.