Evidence map›Paper›PMID 42197888›Full record

ArticleSensors (Basel, Switzerland)2026

AS7341 Spectral Sensor with Machine Learning for Non-Contact Temperature Monitoring in Electrolytic-Plasma Hardening.

Rinat Kussainov, Aikyn Erboluly, Zhanel Bakyt, Nurlat Kadyrbolat, Rinat Kurmangaliyev, Bauyrzhan Rakhadilov, Vladislav Koc, Aknur Rakhmetollayeva, Zarina Satbayeva

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rinat KussainovEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.ORCID 0000-0001-5166-4761
Aikyn ErbolulyEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.
Zhanel BakytEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.
Nurlat KadyrbolatEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.ORCID 0009-0003-9014-4023
Rinat KurmangaliyevEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.ORCID 0009-0008-2209-6740
Bauyrzhan RakhadilovDepartment of Technical Physics and Heat Power Engineering, Research School of Physical and Chemical Sciences, Shakarim University, Semey 071412, Kazakhstan.
Vladislav KocEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.
Aknur RakhmetollayevaEngineering Center "Strengthening Technologies and Coatings", Shakarim University, Semey 071412, Kazakhstan.
Zarina SatbayevaDepartment of Technical Physics and Heat Power Engineering, Research School of Physical and Chemical Sciences, Shakarim University, Semey 071412, Kazakhstan.ORCID 0000-0001-7161-2686

Funding

Ministry of Science and Higher Education of the Republic of Kazakhstan BR24992870
6 · The paper itself

Abstract

Electrolytic-plasma hardening of steel components requires reliable non-contact temperature monitoring, but traditional pyrometry is complicated by the variable emissivity of steel and the intense radiation of the plasma envelope. This work presents an approach that repurposes a compact multispectral AS7341 sensor into a virtual temperature sensor based on physically grounded spectral feature engineering and regularized machine learning. The use of logarithmic ratios of the near-infrared channel (940 nm) to the visible channels suppresses the plasma contribution and linearizes Wien's radiation law. On a controlled dataset of 20 cycles, this increases the Pearson correlation with the peak temperature from r = 0.498 (raw NIR channel) to r = 0.781 for the log(NIR/Clear) feature. Current is identified as a confounding variable; normalizing the NIR/Clear ratio by the cycle-averaged current (r = 0.761) ensures correct signal interpretation under varying process conditions. Two narrow channels-NIR (940 nm) and F8 (680 nm)-provide accuracy equivalent to the broadband Clear channel (r = 0.778 vs. 0.781), thus simplifying hardware implementation. Ridge regression using three weakly correlated features (log(NIR/Clear), cycle duration, and initial temperature) achieves a mean absolute error of 91.4 °C under leave-one-out cross-validation (LOOCV) and 85.5 °C on an independent current-group test (R

Indexed as

AS7341electrolytic-plasma hardeningfeature selectionmachine learningmetallographic analysismicrohardnessNIR/Clearnon-contact temperature measurementregression models

Identifiers

PMID42197888
PMCPMC13210479

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.