ArticleSensors (Basel, Switzerland)2026
RA-BiMENet: Continuous-Time 4D Medical Image Interpolation via Relation-Aware Bi-Directional Motion Estimation.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Four-dimensional medical images introduce the temporal dimension to three-dimensional spatial data, enabling the dynamic characterization of organ motion and providing important support for disease diagnosis and functional assessment. However, due to constraints such as low-dose acquisition and prolonged scanning, the challenges faced in obtaining 4D medical images with high temporal resolution include insufficient spatial sampling, severe motion artifacts, and image blurring. Therefore, generating high-quality and temporally continuous intermediate frames while ensuring patient safety remains a critical challenge in 4D medical image interpolation. To address this issue, we propose the Relation-Aware Bi-directional Motion Estimation Network (RA-BiMENet) for 4D medical image interpolation, which enables the accurate prediction of intermediate frames at arbitrary time points. Specifically, RA-BiMENet consists of two key components: a spatiotemporal transform MLP (TS-MLP) module and a hierarchical spatiotemporal fusion (HSTF) module. The TS-MLP module performs bi-directional motion estimation in a pyramid-recursive manner, where a relation-aware multi-scale MLP (RAM-MLP) unit is introduced to model local correlations and multi-scale dependencies for accurate nonlinear motion estimation. Based on the estimated transformations, the HSTF module hierarchically integrates cross-temporal features through forward warping and self-attention, thereby enhancing local detail restoration while preserving global temporal consistency. Experimental results demonstrate that RA-BiMENet outperforms state-of-the-art methods on multiple quantitative evaluation metrics and is capable of generating high-fidelity and temporally coherent interpolated frames under complex deformation scenarios, validating its effectiveness and superiority for continuous-time 4D medical image interpolation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.