Evidence map›Paper›PMID 42197783›Full record

ArticleSensors (Basel, Switzerland)2026

Optimal Control Method for Microgrid Distributed Generation Based on Multi-Agent Adaptive Decision-Making.

Hao Mai, Qinfang Teng, Xiaojian Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hao MaiCollege of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730050, China.ORCID 0009-0004-4811-4653
Qinfang TengCollege of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730050, China.ORCID 0000-0003-1531-1138
Xiaojian WangCollege of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730050, China.ORCID 0009-0006-9312-1507

Funding

Lanzhou Municipal Science and Technology Bureau: Science and Technology Plan Project 2025-5-008Science and Technology Department of Gansu Province: Science and Technology Plan Project 24CXGA013
6 · The paper itself

Abstract

In addressing the challenges of strong power generation fluctuation, complex load variation, and dynamic topology changes in microgrid operation, this paper puts forward a proposal for optimal control methodology for distributed generation based on multi-agent adaptive decision-making. The initial conception of the dynamic strategy optimization module is to facilitate online learning and continuous optimization of agent decision-making capabilities. This objective is realized through the construction of a topology correlation matrix, which is based on microgrid operation data. The subsequent generation of preliminary control actions is facilitated by a multi-agent adaptive decision network. Concurrently, a safety optimization model founded upon the barrier Lyapunov function has been developed. The model has been designed to facilitate collaborative correction and safety constraint verification of the preliminary actions, thereby producing final control actions that satisfy global optimization and safe operation requirements. On this basis, an enhanced execution control module is employed, incorporating adaptive ramp rate limitations to calculate the target power reference, achieving high precision and fast tracking of power commands. The findings from both simulation and experimental studies demonstrate that, in complex scenarios such as load fluctuations and topology reconfiguration, the proposed method maintains voltage fluctuations within 1.6 V, achieves frequency recovery within 0.01 s, ensures a rapid power sharing response with a small steady-state error, and improves system operational economy by approximately 8.2% compared to conventional distributed control methods. This enhancement of dynamic adaptability, operational safety, and economic performance of the microgrid is therefore significant.

Indexed as

distributed generationmicrogridmulti-agent

Identifiers

PMID42197783
PMCPMC13211175

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.